Extensively porous-coated stems for femoral revision: reliable choice for stem revision in Paprosky femoral type III defects.

نویسندگان

  • Lien-Hsiang Chung
  • Po-Kuei Wu
  • Cheng-Fong Chen
  • Wei-Ming Chen
  • Tain-Hsiung Chen
  • Chien-Lin Liu
چکیده

Between January 1999 and August 2008, ninety-six femoral revisions were performed with extensively porous-coated stems in Paprosky type III femoral defects (89 type IIIA and 7 type IIIB defects). Seven type IIIB defects with a mean canal of 16.5 mm were observed; 6 defects achieved stable bone ingrowth and 1 achieved stable fibrous condition. Average postoperative Harris Hip Score was 92.3±8 (range, 77-100), and all scores improved postoperatively. At a mean follow-up of 65.7 months, 92 stems achieved bone ingrowth, and 1 stem (type IIIB) achieved a stable fibrous condition. Three patients died from causes unrelated to the surgery during follow-up. The most frequent diagnosis for revision of the femoral component was loosening of the cementless stem (53 patients; 55.2%), followed by status after a Girdlestone procedure (21 patients; 21.8%), after total hip arthroplasty with acetabular wear (10 patients; 10.4%), loosening of the cemented stem (7 patients; 7.3%), and periprosthetic fracture (5 patients; 5.2%). The authors performed 65 total hip arthroplasty revisions, 23 femoral component revisions, and 8 revisions of femoral components with cemented liners in patients with well-fixed acetabular shells. Extensively porous-coated stems in femoral revision for Paprosky type III femoral defects provided good mid-term durability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive hollow trephine technique is recommended for revision of broken uncemented and extensively porous-coated monolithic femoral stems: a review of three cases.

Revisions of fractured, uncemented and extensively porous-coated femoral stems are challenging. In this article, we report three cases of revision surgeries for broken, cementless, and extensively porous-coated femoral stems with Solution stems (DePuy, Warsaw, Indiana). In all cases, minimally invasive endofemoral revision was successfully performed without femoral osteotomy or cortical fenestr...

متن کامل

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

BACKGROUND To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty. METHODS This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiologica...

متن کامل

Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem

BACKGROUND AND PURPOSE Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. PATIENTS AND METHODS We retros...

متن کامل

Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

BACKGROUND Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. METHODS Twenty-four cadaveric femoral specimens were implanted with...

متن کامل

Fractures of distally-fixed femoral stems after revision arthroplasty.

We identified five (2.3%) fractures of the stem in a series of 219 revision procedures using a cementless, cylindrical, extensively porous-coated, distally-fixed femoral stem. Factors relating to the patients, the implant and the operations were compared with those with intact stems. Finite-element analysis was performed on two of the fractured implants. Factors associated with fracture of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 2012