OBJECTIVE To determine the microchemical and surface composition of tibial plateau leveling osteotomy (TPLO) plates before and after explantation. SAMPLE POPULATION 7 TPLO plates surgically removed from host dogs 6 to 54 months after implantation; 2 raw unpolished-and-unpassivated 316L TPLO plates; and 2 heat-treated, polished-and-passivated, and cleaned 316L TPLO plates. PROCEDURES Samples were removed by use of standard techniques to ensure the plate surface was not damaged. Sample pieces were dissolved and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) to determine bulk elemental composition. Other sample pieces were investigated by use of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and x-ray photoelectron spectroscopy (XPS) for determination of sample morphology, near-surface elemental composition, and surface elemental composition, respectively. To investigate the possibility of corrosion in situ, some samples were chemically corroded and analyzed. RESULTS ICP-MS confirmed that elemental composition of samples was consistent with 316L stainless steel. The SEM and EDS analyses revealed trace amounts of polishing materials and a nonuniform carbonaceous biofilm on < 1% of the surface area of samples removed from the host dogs. The XPS analysis indicated an increase in the chromium-to-iron ratio on passivated surfaces, with no difference between passivated samples before implantation and after explantation. CONCLUSIONS AND CLINICAL RELEVANCE Composition of the TPLO plates was consistent with 316L stainless steel. No chemical or topographic changes were detected in TPLO plates that had been implanted in dogs for up to 54 months. A small amount of biofilm was evident on the surface of 2 plates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of tibial plateau leveling on stability of the canine cranial cruciate-deficient stifle joint: an in vitro study.

OBJECTIVE To evaluate the effect of tibial plateau leveling on joint motion in canine stifle joints in which the cranial cruciate ligament (CCL) had been severed. STUDY DESIGN In vitro cadaver study. ANIMALS Six canine cadaver hind legs. METHODS Radiographs of the stifle joints were made to evaluate the tibial plateau angle with respect to the long axis of the tibia. The specimens were mo...

متن کامل

TPLO Plates: Look to Manufacturing Method

Tibial plateau–leveling osteotomy (TPLO) is an increasingly popular method for treating anterior cruciate ligament ruptures in dogs. In recent years, there have been anecdotal reports of neoplasia near plate implantation sites. In this study, metallurgic analysis was performed on 3 new Slocum TPLO plates, 8 retrieved TPLO plates, and 1 new Synthes dynamic compression plate. The 3 new Slocum pla...

متن کامل

A prospective evaluation of the effect of extracorporeal shock wave therapy on patellar ligament desmitis following tibial plateau leveling osteotomy

Introduction: Inflammation of the patellar ligament has been reported as a common complication following the tibial plateau leveling osteotomy (TPLO) procedure. This inflammation of the patellar ligament can range from asymptomatic radiographic thickening to clinical desmitis. Extracorporeal shock wave therapy (ESWT) is a relatively new treatment for various musculoskeletal conditions, includin...

متن کامل

A retrospective study of tibial plateau translation following tibial plateau levelling osteotomy stabilisation using three different plate types.

OBJECTIVE To retrospectively evaluate mediolateral translation of the proximal tibial segment (tibial plateau) after tibial plateau levelling osteotomy (TPLO), stabilised with three types of plate. METHOD Pre- and postoperative radiographs of 79 dogs that had TPLO surgery using three different types of plates were reviewed. Two plate types incorporated non-locking screws: Slocum (22 cases) an...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of veterinary research

دوره 68 8  شماره 

صفحات  -

تاریخ انتشار 2007