Effects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.
نویسندگان
چکیده
BACKGROUND Although plastic arterial sampling syringes are now commonly used, the effects of sample storage time and temperature on blood gas tensions are poorly described for samples with a high oxygen partial pressure (PaO2) taken with these high density polypropylene syringes. METHODS Two ml samples of tonometered whole blood (PaO2 86.7 kPa, PaCO2 4.27 kPa) were placed in glass syringes and in three brands of plastic blood gas syringes. The syringes were placed either at room temperature or in iced water and blood gas analysis was performed at baseline and after 5, 10, 20, 40, 60, 90, and 120 minutes. RESULTS In the first 10 minutes measured PaO2 in plastic syringes at room temperature fell by an average of 1.21 kPa/min; placing the sample on ice reduced the rate of PaO2 decline to 0.19 kPa/min. The rate of fall of PaO2 in glass at room temperature was 0.49 kPa/min. The changes in PaCO2 were less dramatic and at room temperature averaged increases of 0.47 kPa for plastic syringes and 0.71 kPa for glass syringes over the entire two hour period. These changes in gas tension for plastic syringes would lead to an overestimation of pulmonary shunt measured by the 100% oxygen technique of 0.6% for each minute left at room temperature before analysis. CONCLUSIONS Glass syringes are superior to plastic syringes in preserving samples with a high PaO2, and prompt and adequate cooling of such samples is essential for accurate blood gas analysis.
منابع مشابه
Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test.
At the present time, plastic syringes are most commonly used for collecting arterial blood. The oxygen tension of the arterial blood (Pa,O2) in these syringes may fall. We studied the effect of the type of syringe, metabolism, and storage time on the arterial oxygen pressures measured and on the pulmonary shunt calculated. In 10 patients, 2-3 h after aortacoronary bypass surgery, a 100% oxygen ...
متن کاملEffects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples.
BACKGROUND The practice of on-ice storage of arterial-blood samples in plastic syringes for delayed analysis continues, and the effects of storage time and temperature on the measurement of blood-oxygen-saturation values (S(aO2)) have not been adequately described. OBJECTIVE To determine the effects of syringe material, storage time, and storage temperature on normal arterialized blood gas an...
متن کاملOf time and temperature, plastic and glass: specimen handling in the blood-gas laboratory.
Character actor Walter Burke spoke his famous line about “plastics” just about the time that syringes made of plastic were being widely introduced to the medical marketplace. Plastics have taken hold in just about every aspect of modern life, including health care. Plastics equate to disposability, a characteristic that makes them valuable for eliminating cross-contamination in almost every are...
متن کاملEffect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
BACKGROUND Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. OBJECTIVES To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. PATIENTS AND METHODS 2.5 mL arterial blood samples were dr...
متن کاملEffects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...