Manifest variable path analysis: potentially serious and misleading consequences due to uncorrected measurement error.
نویسندگان
چکیده
Despite clear evidence that manifest variable path analysis requires highly reliable measures, path analyses with fallible measures are commonplace even in premier journals. Using fallible measures in path analysis can cause several serious problems: (a) As measurement error pervades a given data set, many path coefficients may be either over- or underestimated. (b) Extensive measurement error diminishes power and can prevent invalid models from being rejected. (c) Even a little measurement error can cause valid models to appear invalid. (d) Differential measurement error in various parts of a model can change the substantive conclusions that derive from path analysis. (e) All of these problems become increasingly serious and intractable as models become more complex. Methods to prevent and correct these problems are reviewed. The conclusion is that researchers should use more reliable measures (or correct for measurement error in the measures they do use), obtain multiple measures for use in latent variable modeling, and test simpler models containing fewer variables.
منابع مشابه
An application of Measurement error evaluation using latent class analysis
Latent class analysis (LCA) is a method of evaluating non sampling errors, especially measurement error in categorical data. Biemer (2011) introduced four latent class modeling approaches: probability model parameterization, log linear model, modified path model, and graphical model using path diagrams. These models are interchangeable. Latent class probability models express l...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملComparison of self-refraction using a simple device, USee, with manifest refraction in adults
BACKGROUND The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. METHODS Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifes...
متن کاملDEVELOPMENT OF PRODUCTIVITY MEASUREMENT AND ANALYSIS FRAMEWORK FOR MANUFACTURING COMPANIES
The purpose of this research is to present an alternative approach for measuring productivity in manufacturing companies. To achieve the research objective, an in depth investigation on the existing productivity measurement and analysis practices of a case manufacturing company has been carried out through both qualitative and quantitative approaches. The investigation result has shown that the...
متن کاملPerformance Analysis Of Mono-bit Digital Instantaneous Frequency Measurement (Difm) Device
Instantaneous Frequency Measurement (IFM) devices are the essential parts of anyESM, ELINT, and RWR receiver. Analog IFMs have been used for several decades. However, thesedevices are bulky, complex and expensive. Nowadays, there is a great interest in developing a wideband, high dynamic range, and accurate Digital IFMs. One Digital IFM that has suitably reached allthese requirements is mono-bi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Psychological methods
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2014