Entropy indices vs the bispectral index for estimating nociception during sevoflurane anaesthesia.
نویسندگان
چکیده
BACKGROUND It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in estimating nociception during sevoflurane anaesthesia. METHODS Forty female patients were enrolled in the present study. Each patient was allocated randomly to one of four end-tidal sevoflurane concentration (ET(sev)) groups (1.3, 1.7, 2.1 or 2.5%). A BIS Sensor (Aspect Medical Systems, Newton, MA) and an Entropy Sensor (Datex-Ohmeda) were applied side-by-side to the forehead. The bispectral index (A-2000 BIS Monitor, version 3.4, Aspect Medical Systems), response entropy, state entropy and patient movement were observed after electrical stimulation (20, 40, 60 and 80 mA, 100 Hz, 5 s) and after skin incision during sevoflurane anaesthesia (1.3, 1.7, 2.1 or 2.5%). Accuracy of the EEG variables in differentiating the intensity of electrical stimulation was estimated by the prediction probability (P(K)) values. RESULTS Response entropy and state entropy [median, (range)] before skin incision were significantly lower in patients who did not move [29 (15-41) and 24 (14-41)] than in those that did [38 (24-53) and 37 (24-52)], but there was no significant difference in BIS. All EEG variables increased significantly (P<0.0001 for all) with increases in the intensity of electrical stimulation. The difference between response entropy and state entropy increased with increases in the electrical stimulation (P<0.0001). However, no EEG variables could differentiate the intensity of the electrical stimulations accurately because of low P(K)-values (P(K)<0.8). CONCLUSION Noxious stimulation increased the difference between response entropy and state entropy. However, an increase in the difference does not always indicate inadequate analgesia and should be interpreted carefully during anaesthesia.
منابع مشابه
Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane.
BACKGROUND Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed the changes in the raw EEG signal during surgical anaesthesia with sevoflurane. METHODS...
متن کاملInfluence of different remifentanil concentrations on the performance of the surgical stress index to detect a standardized painful stimulus during sevoflurane anaesthesia.
BACKGROUND Although measurement of cerebral hypnotic drug effect and muscle relaxation is common clinical routine during anaesthesia, a reliable measurement of the neurophysiological effects evoked by a painful stimulus is still missing. Recently, the surgical stress index (SSI) has been introduced as a surrogate measure of 'nociception'. The present study aimed to examine the influence of incr...
متن کاملEffect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia.
BACKGROUND beta1-Adrenoceptor antagonists suppress the haemodynamic and arousal responses to tracheal intubation. The Entropy Module shows two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE) may reflect nociception during general anaesthesia. In the present study, we investigated the effect of landiolol on entropy indices in...
متن کاملRocuronium dose-dependently suppresses the spectral entropy response to tracheal intubation during propofol anaesthesia.
BACKGROUND The Entropy Module anaesthesia monitor displays two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE), which mainly reflects electromyography activation, is thought to indicate the adequacy of antinociception. Little is known, however, about the effects of neuromuscular blocking agents on the RE-SE. We investigated ...
متن کاملThe performance of Bispectral Index in children during equi-MAC halothane vs. sevoflurane anaesthesia.
BACKGROUND AND OBJECTIVE The reliability of the Bispectral Index for evaluating and monitoring the depth of general anaesthesia in children is not as great as for that in adults. Therefore we analysed Bispectral Index performance in children by comparing changes in Bispectral Index values during a standardized and equipotent anaesthetic regimen using either halothane or sevoflurane for the indu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 96 5 شماره
صفحات -
تاریخ انتشار 2006