Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness
نویسندگان
چکیده
BACKGROUND Cardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT) in evaluating treatment response. We tested the hypothesis that 6-month statin treatment in patients with carotid plaque will lead to plaque regression when measured by 3 Tesla CMR but not by IMT. METHODS Twenty-six subjects (67 ± 2 years, 7 females) with known carotid plaque (> 1.1 mm) and coronary or cerebrovascular atherosclerotic disease underwent 3T CMR (T1, T2, proton density and time of flight sequences) and US at baseline and following 6 months of statin therapy (6 had initiation, 7 had increase and 13 had maintenance of statin dosing). CMR plaque volume (PV) was measured in the region 12 mm below and up to 12 mm above carotid flow divider using software. Mean posterior IMT in the same region was measured. Baseline and 6-month CMR PV and US IMT were compared. Change in lipid rich/necrotic core (LR/NC) and calcification plaque components from CMR were related to change in PV. RESULTS Low-density lipoprotein cholesterol decreased (86 ± 6 to 74 ± 4 mg/dL, p = 0.046). CMR PV decreased 5.8 ± 2% (1036 ± 59 to 976 ± 65 mm3, p = 0.018). Mean IMT was unchanged (1.12 ± 0.06 vs. 1.14 ± 0.06 mm, p = NS). Patients with initiation or increase of statins had -8.8 ± 2.8% PV change (p = 0.001) while patients with maintenance of statin dosing had -2.7 ± 3% change in PV (p = NS). There was circumferential heterogeneity in CMR plaque thickness with greatest thickness in the posterior carotid artery, in the region opposite the flow divider. Similarly there was circumferential regional difference in change of plaque thickness with significant plaque regression in the anterior carotid region in region of the flow divider. Change in LR/NC (R = 0.62, p = 0.006) and calcification (R = 0.45, p = 0.03) correlated with PV change. CONCLUSIONS Six month statin therapy in patients with carotid plaque led to reduced plaque volume by 3T CMR, but ultrasound posterior IMT did not show any change. The heterogeneous spatial distribution of plaque and regional differences in magnitude of plaque regression may explain the difference in findings and support volumetric measurement of plaque. 3T CMR has potential advantage over ultrasound IMT to assess treatment response in individuals and may allow reduced sample size, duration and cost of clinical trials of plaque regression.
منابع مشابه
Carotid black blood MRI burden of atherosclerotic disease assessment correlates with ultrasound intima-media thickness.
The aim of this study was to correlate carotid black blood MRI based measurements with those obtained by ultrasound intima-media thickness (IMT). Seventeen patients with intermediate to high Framingham cardiovascular risk score underwent both carotid ultrasound and rapid extended coverage double inversion recovery black blood carotid MRI. Overall, there was good correlation between wall area, w...
متن کاملComparison of the Intima-media Thickness of Carotid Artery in Children with Diabetes Type One and Control Group Using Ultrasound
Background & Aims: Diabetes is a very important factor for stroke due to blocked blood vessels. It can involve systemic and cerebrovascular arteries at the same time via microangiopathy and macroangiopathy. This project aimed to compare the intima-media thickness of carotid artery in children with diabetes type and the control group. Methods: In this case-control study, 50 children with the age...
متن کاملStabilization of carotid atheroma assessed by quantitative ultrasound analysis in nonhypercholesterolemic patients with coronary artery disease.
OBJECTIVES This study examined whether intensive cholesterol-lowering therapy with statins in nonhypercholesterolemic patients is effective in improving echolucency of vulnerable plaques assessed by ultrasound with integrated backscatter (IBS) analysis. BACKGROUND Atherosclerotic plaque stabilization is a promising clinical strategy to prevent cardiovascular events in patients with coronary a...
متن کاملIs carotid intima-media thickness as predictive as other noninvasive techniques for the detection of coronary artery disease?
Carotid intima-media thickness (CIMT) measured by B-mode ultrasound is the most widely used noninvasive imaging method to assess atherosclerosis and cardiovascular risk. CIMT has been consistently associated with coronary artery disease and stroke; however, recent meta-analyses and systematic reviews suggest that its clinical usefulness may be limited because the addition of CIMT to traditional...
متن کاملRed Blood Cell Eicosapentaenoic Acid Inversely Relates to MRI-Assessed Carotid Plaque Lipid Core Burden in Elders at High Cardiovascular Risk
Supplemental marine omega-3 eicosapentaenoic acid (EPA) has an anti-atherosclerotic effect. Clinical research on EPA supplied by the regular diet and atherosclerosis is scarce. In the framework of the PREvención con DIeta MEDiterránea (PREDIMED) trial, we conducted a cross-sectional study in 161 older individuals at high vascular risk grouped into different stages of carotid atherosclerosis sev...
متن کاملذخیره در منابع من