Analysis of the hydrodynamic profile in different roller pumps models used in cardiopulmonary bypass.

نویسندگان

  • Francisco Ubaldo Vieira
  • Reinaldo Wilson Vieira
  • Nilson Antunes
  • Orlando Petrucci
  • Pedro Paulo de Oliveira
  • Márcia Milena Pivatto Serra
  • Karlos Alexandre de Sousa Vilarinho
  • Marcio Roberto do Carmo
چکیده

OBJECTIVE Among the equipments used in cardiopulmonary bypass the roller pumps have great importance with various models available from several manufacturers. The calibration is an important factor in hemolysis rates and its potential is different in each. Researchers do not always approach details on the pump bed profiles assuming that the standardized calibration settings ensure equal and comparable values for all models of roller pumps. We have mainly two methods for calibration of pumps which also interferes on the hemolytic potential. In both of them, the characteristics of fluid impulsion defined by the pump bed design are not considered. The aim of this study is to compare the hydrodynamic profile of three models of roller pumps available in the Brazilian market. METHOD The rollers occlusion was performed by measures of drop and dynamic calibration. Two different silicone diameter tubes were used (3/8 x 1/16 and 1/2 x 3/32 inches). RESULTS The profiles showed differences in their variances, P<0.01 for drop rate measures and P<0.0001 for dynamic calibration. Different changes in pressure were found between the pumps analyzed (P<0.002). CONCLUSION The measures of occlusion are dependent on the design of the pump bed and comparisons involving roller pumps should be performed with caution. Blood tests should be performed to verify the influence of changes in hemolysis pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

History of extracorporeal circulation: the invention and modification of blood pumps.

The first roller pump was patented in 1855 by Porter and Bradley and was hand operated. A modification first named "surgical pump", designed and manufactured by E. E. Allen in 1887, was intended for direct blood transfusion. Truax, who also distributed and promoted the Allen pump with one roller, developed the first double roller pump in 1899. In the following decades, several researchers, incl...

متن کامل

Flow visualization in blood aspirator and cardiotomy reservoir used in cardiopulmonary bypass.

OBJECTIVE One of the major damage caused by occlusion in roller pumps is hemolysis. Comparative studies between roller pump with adjustments non occlusive and centrifugal pumps have been made in recent decades in an attempt to develop new products and adjustments that cause fewer traumas to the figurative elements of blood. Usually the roller pumps are adjusted by the static method due to conce...

متن کامل

Blood flow and damage by the roller pumps during cardiopulmonary bypass

Although much CFD work has been carried out to study the blood damage created in a centrifugal pump used for a cardiopulmonary bypass, little is known about the blood flow and consequent damage in a roller pump. A timedependent moving boundary problem is solved in this paper to explore the blood flow and damage in the roller pump. An initial attempt to predict the blood damage from these simula...

متن کامل

Significant safety advantages gained with an improved pressure-regulated blood pump.

A prototype of a non-occlusive pressure-regulated blood pump (M-pump) was evaluated in-vitro for safety in a comparative study with the roller and centrifugal pumps. The M-pump consists of collapsible tubing of unique design wrapped under tension around a rotor without a stator. The prototype M-pumps were tested in vitro to evaluate performance with respect to flow/ pressure characteristics, he...

متن کامل

Effect of different pump heads for CPB on early cognitive outcome after coronary artery bypass surgery.

OBJECTIVES Reduction of cognitive function is a possible side effect after coronary artery surgery using cardiopulmonary bypass (CPB). We investigated the effect of roller versus centrifugal pumps for CPB on cognitive performance in patients undergoing coronary artery bypass grafting (CABG). METHODS 50 consecutive CABG patients operated with centrifugal pump were compared to 50 roller pump pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 2009