Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems
نویسندگان
چکیده
BACKGROUND Acinetobacter species are the leading cause of bloodstream infection (BSI), but their correct identification is challenging. We evaluated the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based VITEK MS (bioMérieux, France), and two automated systems, VITEK 2 (bioMérieux) and MicroScan (Siemens, USA) for identification of Acinetobacter BSI isolates. METHODS A total of 187 BSI isolates recovered at a university hospital in Korea between 2010 and 2012 were analyzed. The identification results obtained using VITEK MS and two automated systems were compared with those of rpoB sequencing. RESULTS Of 187 isolates analyzed, 176 were identified to the species level by rpoB sequencing: the Acinetobacter baumannii group (ABG; 101 A. baumannii, 43 A. nosocomialis, 10 A. pittii isolates) was most commonly identified (82.4%), followed by Acinetobacter genomic species 13BJ/14TU (5.3%), A. ursingii (2.1%), A. soli (2.1%), A. bereziniae (1.1%), and A. junii (1.1%). Correct identification rates to the species group (ABG) level or the species level was comparable among the three systems (VITEK MS, 90.3%; VITEK 2, 89.2%; MicroScan, 86.9%). However, VITEK MS generated fewer misidentifications (0.6%) than VITEK 2 (10.8%) and MicroScan (13.1%) (P<0.001). In addition, VITEK MS demonstrated higher specificity (100%) for discrimination between ABG and non-ABG isolates than the other systems (both, 31.8%) (P<0.001). CONCLUSIONS The VITEK MS system is superior to the VITEK 2 and MicroScan systems for identification of Acinetobacter BSI isolates, with fewer misidentifications and better discrimination between the ABG and non-ABG isolates.
منابع مشابه
Oligonucleotide Array and VITEK Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Species Identification of Blood Yeast Isolates
We evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry using VITEK MS (IVD database) and an oligonucleotide array based on the internal transcribed spacer-1 (ITS-1) and ITS-2 sequences of rRNA genes for the identification of Candida spp. from blood cultures. Five-hundred and twelve consecutive bloodstream yeast isolates were collected daily and initially ident...
متن کاملAccuracy of species-level identification of yeast isolates from blood cultures from 10 university hospitals in South Korea by use of the matrix-assisted laser desorption ionization-time of flight mass spectrometry-based Vitek MS system.
We assessed the accuracy of yeast bloodstream isolate identification performed over a 1-year period at 10 South Korean hospitals, using the matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based Vitek MS system. The overall phenotypic misidentification rate was 3.4% (18/533), with considerable variation between hospitals (0.0% to 19.0%), compared to 1.1% (6/533) for the Vi...
متن کاملRapid Diagnosis of Mycobacterium abscessus Bacteremia Using Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry
Mycobacterium abscessus was isolated from cultures of seven blood samples from a 64-year-old diabetic female who was admitted due to steroid-unresponsive adrenal insufficiency. The isolates were difficult to identify using the conventional commercial systems, VITEK 2 (bioMérieux, France) or MicroScan (Siemens Healthcare Diagnostics, USA), but were rapidly identified as M. abscessus by a matrix-...
متن کاملAn extraction method of positive blood cultures for direct identification of Candida species by Vitek MS matrix-assisted laser desorption ionization time of flight mass spectrometry.
Candida spp. are an important cause of nosocomial bloodstream infections. Currently, complete identification of yeasts with conventional methods takes several days. We report here the first evaluation of an extraction method associated with the Vitek MS matrix-assisted laser desorption ionization time of flight mass spectrometry for direct identification of Candida species from positive blood c...
متن کاملPerformance of the VITEK MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for rapid bacterial identification in two diagnostic centres in China.
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS systems was not officially launched for diagnostic use in clinical microbiology laboratories in China until 2012. Here, we report the findings from the first large-scale evaluation study of VITEK MS for routine bacterial identification in two major diagnostic centres in Beijing and Hong Kong. A total of 2266 unique isolat...
متن کامل