Improved Cardiac MRI Volume Measurements in Patients with Tetralogy of Fallot by Independent End-Systolic and End-Diastolic Phase Selection

نویسندگان

  • Hendrik G. Freling
  • Petronella G. Pieper
  • Karin M. Vermeulen
  • Jeroen M. van Swieten
  • Paul E. Sijens
  • Dirk J. van Veldhuisen
  • Tineke P. Willems
چکیده

OBJECTIVES To investigate to what extent cardiac MRI derived measurements of right ventricular (RV) volumes using the left ventricular (LV) end-systolic and end-diastolic frame misrepresent RV end-systolic and end-diastolic volumes in patients with tetralogy of Fallot (ToF) and a right bundle branch block. METHODS Sixty-five cardiac MRI scans of patients with ToF and a right bundle branch block, and 50 cardiac MRI scans of control subjects were analyzed. RV volumes and function using the end-systolic and end-diastolic frame of the RV were compared to using the end-systolic and end-diastolic frame of the LV. RESULTS Timing of the RV end-systolic frame was delayed compared to the LV end-systolic frame in 94% of patients with ToF and in 50% of control subjects. RV end-systolic volume using the RV end-systolic instead of LV end-systolic frame was smaller in ToF (median -3.3 ml/m(2), interquartile range -1.9 to -5.6 ml/m(2); p<0.001) and close to unchanged in control subjects. Using the RV instead of LV end-systolic and end-diastolic frame hardly affected RV end-diastolic volumes in both groups and ejection fraction in control subjects (54±4%, both methods), while increasing ejection fraction from 45±7% to 48±7% for patients with ToF (p<0.001). QRS duration correlated positively with the changes in the RV end-systolic volume (p<0.001) and RV ejection fraction obtained in ToF patients when using the RV instead of the LV end-systolic and end-diastolic frame (p = 0.004). CONCLUSION For clinical decision making in ToF patients RV volumes derived from cardiac MRI should be measured in the end-systolic frame of the RV instead of the LV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

ارزیابی نتایج میان مدت جراحی تعویض دریچه پولمونر در بیماران با سابقه جراحی ترمیم کامل تترالوژی فالو در مرکز قلب و عروق شهید رجایی تهران، ایران

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes ms...

متن کامل

Echocardiographic assessment of right ventricular volumes after surgical repair of tetralogy of Fallot: clinical validation of a new echocardiographic method.

BACKGROUND Assessment of right ventricular (RV) volumes and function is important in patients after tetralogy of Fallot (TOF) repair. Currently, cardiac magnetic resonance imaging (MRI) is considered the clinical reference method for RV volume and function measurements. Three-dimensional (3D) knowledge-based reconstruction derived from two-dimensional echocardiographic imaging with magnetic tra...

متن کامل

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

BACKGROUND Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. METHODS Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot d...

متن کامل

Magnetic resonance imaging to assess the hemodynamic effects of pulmonary valve replacement in adults late after repair of tetralogy of fallot.

BACKGROUND Pulmonary regurgitation (PR) late after total correction for tetralogy of Fallot may lead to progressive right ventricular (RV) dilatation and an increased incidence of severe arrhythmias and sudden death. Timing of pulmonary valve replacement (PVR) is subject to discussion, because the effect of PVR on RV function in adults is unclear. In this study, MRI was used to assess the effec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013