Optimizing the precision of a multichannel three-polarizer spectroscopic ellipsometer.

نویسندگان

  • Won Chegal
  • Jeong Pyo Lee
  • Hyun Mo Cho
  • Sang-Wook Han
  • Yong Jai Cho
چکیده

We developed a multichannel three-polarizer spectroscopic ellipsometer based on a data acquisition algorithm for achieving optimized precision. This algorithm measures unnormalized Fourier coefficients accurately and precisely. Offset angles for optical elements were obtained as wavelength-independent values using regression calibration. Derived subsets of data reduction functions were used to calculate sample parameters. Correlation coefficients of Fourier coefficients were used to calculate errors in the sample parameters. Mean standard deviations of the sample parameters for each data reduction method were compared to identify the best method. This approach could be used to identify suitable precision optimization methods for other rotating-element ellipsometers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zone-averaged method to minimize polarizer and analyzer imperfections in a phase-modulated spectroscopic ellipsometer

We have theoretically investigated the effects of polarizer and analyzer imperfections in a phase-modulated spectroscopic ellipsometer adopting a photoelastic modulator. Jones matrices having off-diagonal elements have been introduced to represent the imperfections of the polarizer and analyzer, and the effects of the imperfections were analytically derived to the first-order approximation. It ...

متن کامل

Multichannel Mueller matrix ellipsometer based on the dual rotating compensator principle

A multichannel ellipsometer in the dual rotating-compensator configuration has been designed and constructed for applications in real time Mueller matrix ellipsometry (approx. 2–5 eV) of anisotropic surfaces and films. The sequence of optical elements for this instrument is denoted PC (v )SC (v )A, where P, S, and A represent the polarizer, sample, and analyzer. C (v ) and 1r 1 2r 2 1r 1 C (v )...

متن کامل

Fast, Self-nulling Spectroscopic Ellipsometer : Instrumentation and Application

The advantages of rapid spectral scanning have been combined with -the inherent accuracy of a compensating ellipsometer operated in the polarizer-compensator-sample-analyzer configuration. Wavelength is varied over the visible-UV ( 3 7 0 7 2 0 nm) at a maximum rate of 114 nm/s by rotating a continuously-variable interference filter. A three-reflection Fresnel rhomb serves as the achromatic quar...

متن کامل

One-dimensional Spectroscopic Measurement of Patterned Structures Using a Custom-built Spectral Imaging Ellipsometer

A novel spectral imaging ellipsometer based on a mono-axial power spectrograph has been developed for one-dimensional spectroscopic measurement of patterned structures. To obtain the imaging data of a patterned sample using ellipsometry can be realized by conventional ellipsometers with 2-dimesional (2D) scanning sample stage or 2D imaging ellipsometers with imaging optics. The former has major...

متن کامل

Ellipsometer nulling: convergence and speed.

The process of nulling in ellipsometry is studied by a graphical presentation using the trajectories of two significant polarization states in the complex plane, (XPC) and (XSA). These states are determined by (1) the polarizer and compensator ((XPC)) and (2) the specimen and the analyzer ((XSA)) in the polarizer-compensator-specimen-analyzer ellipsometer arrangement. As the azimuth angles of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 2013