The Kelvin and Temperature Measurements

نویسندگان

  • B. W. Mangum
  • G. T. Furukawa
  • K. G. Kreider
  • C. W. Meyer
  • D. C. Ripple
  • G. F. Strouse
  • W. L. Tew
  • M. R. Moldover
  • B. Carol Johnson
  • H. W. Yoon
  • C. E. Gibson
  • R. D. Saunders
چکیده

The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to 1234.93 K, the temperature range in which the ITS-90 is defined in terms of calibration of thermometers at 15 fixed points and vapor pressure/temperature relations which are phase equilibrium states of pure substances. The realization is accomplished by using fixed-point devices, containing samples of the highest available purity, and suitable temperature-controlled environments. All components are constructed to achieve the defining equilibrium states of the samples for the calibration of thermometers. The high quality of the temperature realization and measurements is well documented. Various research efforts are described, including research to improve the uncertainty in thermodynamic temperatures by measuring the velocity of sound in gas up to 800 K, research in applying noise thermometry techniques, and research on thermocouples. Thermometer calibration services and high-purity samples and devices suitable for "on-site" thermometer calibration that are available to the thermometry community are described. Part II of the paper describes the realization of temperature above 1234.93 K for which the ITS-90 is defined in terms of the calibration of spectroradiometers using reference blackbody sources that are at the temperature of the equilibrium liquid-solid phase transition of pure silver, gold, or copper. The realization of temperature from absolute spectral or total radiometry over the temperature range from about 60 K to 3000 K is also described. The dissemination of the temperature scale using radiation thermometry from NIST to the customer is achieved by calibration of blackbody sources, tungsten-strip lamps, and pyrometers. As an example of the research efforts in absolute radiometry, which impacts the NIST spectral irradiance and radiance scales, results with filter radiometers and a high-temperature blackbody are summarized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Shrinkage-Reducing Admixtures on Early-Age Properties of Cement Pastes

Because most shrinkage-reducing admixtures (SRAs) significantly reduce the surface tension of a cement paste pore solution, they will naturally influence all physical properties and processes that are dependent in some way on surface tension. Such properties include internal relative humidity, capillary stresses, and freezing point depression, all via the Kelvin equation and its variants (Kelvi...

متن کامل

The Moon's Temperature at λ=2.77cm

The study of the thermal radio emission of the moon and planets began in 1946 with the detection of the thermal radiation of the moon at 1.25cm wavelength by Dicke and Beringer [1]. This was followed three years later by a comprehensive series of observations of the radiation from the moon at 1.25cm wavelength over three lunar cycles by Piddington and Minnett [2] showing that the thermal radiat...

متن کامل

Proximity-induced superconductivity in DNA.

Conductivity measurements on double-stranded DNA molecules deposited by a combing process across a submicron slit between rhenium/carbon metallic contacts reveal conduction to be ohmic between room temperature and 1 kelvin. The resistance per molecule is less than 100 kilohm and varies weakly with temperature. Below the superconducting transition temperature (1 kelvin) of the contacts, proximit...

متن کامل

Measuring Translational Temperatures with Degenerate Four-Wave Mixing

We demonstrate a new method for measuring translational temperatures using degenerate four-wave mixing (DFWM). We perform high-resolution measurements of DFWM spectra in both the forward (BoxCARS) and backward (phase-conjugate) phase-matching geometries on nitric oxide (NO) in a room-temperature gas cell. We analyze the spectra with a modified perturbation theory to extract the temperature from...

متن کامل

Effect of light color temperature on selective attention, error rate and reaction time

Investigating the effect of light color temperature on selective attention, error and human reaction time Abstract Background and aims: In humans, the reaction time limit is associated with several factors. It includes the time that takes to stimulate the sensory member, the stimulus effect is transmitted to the brain, then is perceived and the decision is made; consequently, the command resu...

متن کامل

Assessment of Vegetation Temperature Status (VTCI) for monitoring drought in the watershed of Lake Urmia by using MODIS satellite imagery

Continuous decline in Lake Urmia water levels In recent years, the decline of rainfall and river flows and constant droughts has become the main concern of the people and the people. To study climate change and increase of temperature in the catchment area of ​​Lake Urmia, two factors for measuring the temperature and properties of satellite images were used which indicate the importance of lan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 106  شماره 

صفحات  -

تاریخ انتشار 2001