The impact of leg length discrepancy on clinical outcome of total hip arthroplasty: comparison of four measurement methods.

نویسندگان

  • Matej Keršič
  • Drago Dolinar
  • Vane Antolič
  • Blaž Mavčič
چکیده

In a single-surgeon series of 119 patients with unilateral primary uncemented total hip arthroplasty, four leg-length discrepancy measurement methods (absolute, relative, trochanteric, standardized-trochanteric) were analyzed for their impact on WOMAC score, Oxford Hip Score and self-perceived leg-length discrepancy. After adjustment for age, gender and BMI, postoperative WOMAC scores correlated only with clinical absolute measurements of leg elongation (P=0.05). Self-perceived leg-length discrepancy corresponded best to the clinically measured relative leg-length discrepancy (11 mm perceived vs. 7 mm unperceived; P=0.04) while there was no significant correspondence with radiographic measurements or leg elongation magnitudes. Within the <10 mm range of mean postoperative leg length discrepancy in the studied series, its impact on the overall clinical satisfaction was detectable but not considerable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

Accurate Leg Length Measurement in Total Hip Arthroplasty: A Comparison of Computer Navigation and a Simple Manual Measurement Device

BACKGROUND Several studies have shown that better placement of the acetabular cup and femoral stem can be achieved in total hip arthroplasty (THA) by using the computer navigation system rather than the free-hand alignment methods. However, there have been no comparisons of the relevant clinical advantages in using the computer navigation as opposed to the manual intraoperative measurement devi...

متن کامل

An intraoperative device to restore femoral offset in total hip arthroplasty

BACKGROUND Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and posto...

متن کامل

Influence of leg length discrepancy on clinical results after total hip arthroplasty--a prospective clinical trial.

The effect of leg length differences on early clinical outcome after total hip arthroplasty remains uncertain. We performed a prospective study on 94 patients who were evaluated preoperatively and one year after surgery for clinical leg length differences, which were then compared with radiological measurements. The effect of leg length differences on walking ability, limp, pain and patient sat...

متن کامل

Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty

Despite concerted intraoperative attempts to establish equal limb alignment, leg length discrepancy (LLD) remains a frequent complication following elective total hip arthroplasty (THA) [1]. A number of effective intraoperative imaging and clinical limb length techniques have been recommended to minimize this complication; however, all of these assessment modalities have their reported limitati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2014