Acceleration and Bunching in a 6 Mv X Band Linac
نویسنده
چکیده
We present detailed beam dynamic simulations in a compact X band accelerator. The accelerator must be capable of delivering an electron beam of 0.5 MW peak at 6 MeV, in order ot produce an X ray dose of 10 Gy/mn at 80 cm for medical applications. The use of a PARMELA like code (DYPAL [1]) allowed us to investigate radial and longitudinal beam dynamics. Important aspects of the calculation were to optimize the bunching, while controlling the radial behavior of the beam. This lead to reduced X ray leakage along the section and high transmitted current ratio from gun to target.
منابع مشابه
Evaluation of Tumor Control and Normal Tissue Complication Probability in Head and Neck Cancers with Different Sources of Radiation: A Comparative Study
Introduction: The ultimate goal of radiation treatment planning is to yield a high tumor control probability (TCP) with a low normal tissue complication probability (NTCP). Historically dose volume histogram (DVH) with only volumetric dose distribution was utilized as a popular tool for plan evaluation hence present study aimed to compare the radiobiological effectiveness of the cobalt-60 (Co...
متن کاملA Compact X-band Linac for an X-ray Fel*
With the growing demand for FEL light sources, cost issues are being reevaluated. To make the machines more compact, higher frequency room temperature linacs are being considered, specifically ones using C-band (5.7 GHz) rf technology, for which 40 MV/m gradients are achievable. In this paper, we show that an X-band (11.4 GHz) linac using the technology developed for NLC/GLC can provide an even...
متن کاملMonte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
متن کاملCompact Hard X-ray Source via Inverse Compton Scattering Based on the X-band Linac
We are designing a compact inverse Compton scattering hard X-ray (33 keV) source based on X-band linac. X-band 1.5and 3.5-cell photocathode RF guns and X-band linac were analyzed with PARMELA simulation, and X-ray flux was estimated for several types of lasers. The theoretical scaling law of the RF guns among charge, emittance, and RF wavelength is confirmed by PARMELA. The maximum RF field at ...
متن کاملThe comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data
Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...
متن کامل