3D Whole-Heart Coronary MR Angiography at 1.5T in Healthy Volunteers: Comparison between Unenhanced SSFP and Gd-Enhanced FLASH Sequences
نویسندگان
چکیده
OBJECTIVE To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). MATERIALS AND METHODS Thirty healthy volunteers (M:F = 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. RESULTS The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. CONCLUSION An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.
منابع مشابه
Whole heart coronary MRA at 3.0T: a comparison between multi and single- RF transmission
Introduction On high field MRI scanners uniform radio frequency (RF) excitation over the entire field-of-view is often challenging with single-channel RF transmit coils. This may cause a reduction of image quality (e.g. shadowing artifacts). This problem is most pronounced in sequences which heavily rely on a homogenous magnetic field, such as steady state free precession (SSFP) sequences, desp...
متن کاملContrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T: comparison with steady-state free precession technique at 1.5 T.
OBJECTIVES To compare contrast-enhanced whole-heart coronary MR angiography (MRA) at 3.0 T and noncontrast steady-state free precession coronary MRA at 1.5 T in the same volunteers. MATERIALS AND METHODS Nine healthy volunteers underwent both coronary MRA using 3D FLASH with slow infusion of MultiHance at 3.0 T and 3D TrueFISP sequence at 1.5 T. Neither beta-blockers nor nitroglycerine was ad...
متن کاملComparison of Respiratory-Triggered (RT) 3D cine steady-state free precession cardiac mri with standard 2D cine imaging and magnetic resonance angiography in Congenital Heart Disease (CHD)
Background This is a pilot study to evaluate the performance of whole-heart isotropic RT-3D cine SSFP sequence as an efficient single solution for assessment of morphology and function in CHD by comparing it to: 1. Short axis (SA) 2D cine SSFP for LV volumetry and function 2. Multiplanar 2D cine SSFP for intracardiac morphology 3. Cine 2D SSFP and gadolinium (Gd)-enhanced 3D MRA for aortic root...
متن کاملCoronary MRA on 3.0T
3.0T has been shown to be a promising platform for coronary MRA. The SNR gain from 1.5T to 3.0T can be traded for improved spatial resolution and/or reduced imaging time. Nevertheless, the SSFP imaging technique that has gained wide acceptance at 1.5T is prone to imaging artifacts at 3.0T because of the increased magnetic field inhomogeneities and RF distortions at higher field strengths. In ad...
متن کاملCardiac MR imaging and MR angiography in pediatric congenital heart disease: a comparison between 1.5T and 3.0T
Background To assess the feasibility of cardiac magnetic resonance imaging (MRI) and angiography (MRA) at 3.0T in pediatric patients with congenital heart disease (CHD) and to compare the technical and diagnostic performance with an age-matched and clinically comparable control group imaged at 1.5T. Methods Forty-six patients (age 1 day to 8 years, mean 37.2 ± 32.8 months) with suspected or kno...