Design considerations for dose-expansion cohorts in phase I trials.

نویسندگان

  • Alexia Iasonos
  • John O'Quigley
چکیده

Phase I trials are increasingly including dose-expansion cohorts after the maximum-tolerated dose (MTD) has been reached to better characterize the toxicity profile or identify early signs of efficacy within a specific disease population. This article provides guidelines on how to monitor safety and re-evaluate the MTD using data obtained from expansion cohorts of phase I protocols. We illustrate how to implement a sequential monitoring rule for safety using a completed phase I trial that included an expansion cohort. We compare the accuracy of the revised MTD with the MTD obtained before expansion and with the true MTD based on simulated trials. The percent of trials that led to a change in the MTD, how far the revised MTD was from the true MTD, and the toxicity rates associated with each level are reported. When toxicity outcomes from the expansion cohort are taken into account, there is a 50% chance that a new, higher MTD will be recommended. Significant improvement in the accuracy of the MTD is obtained 30% of the time (ie, revised MTD is exactly the true MTD), and moderate improvement is obtained 80% of the time when the revised MTD is within a level from true MTD. Failure to include toxicity outcomes from additional patients treated during the expansion phase may result in a less accurate estimate of the MTD. This article provides investigators of phase I protocols with methodological tools to monitor safety and/or efficacy for patients accrued during the expansion phase and to update or confirm the established MTD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose expansion cohorts in Phase I trials.

A rapidly increasing number of Phase I dose-finding studies, and in particular those based on the standard 3+3 design, are being prolonged with the inclusion of dose expansion cohorts (DEC) in order to better characterize the toxicity profiles of experimental agents and to study disease-specific cohorts. These trials consist of two phases: the usual dose escalation phase that aims to establish ...

متن کامل

Statistical controversies in clinical research: requiem for the 3 + 3 design for phase I trials.

BACKGROUND More than 95% of published phase I trials have used the 3 + 3 design to identify the dose to be recommended for phase II trials. However, the statistical community agrees on the limitations of the 3 + 3 design compared with model-based approaches. Moreover, the mechanisms of action of targeted agents strongly challenge the hypothesis that the maximum tolerated dose constitutes the op...

متن کامل

Evaluation of statistical designs in phase I expansion cohorts: the Dana-Farber/Harvard Cancer Center experience.

BACKGROUND Phase I trials have traditionally been designed to assess toxicity and establish phase II doses with dose-finding studies and expansion cohorts but are frequently exceeding the traditional sample size to further assess endpoints in specific patient subsets. The scientific objectives of phase I expansion cohorts and their evolving role in the current era of targeted therapies have yet...

متن کامل

Cancer Therapy: Clinical Is the "3þ3" Dose-Escalation Phase I Clinical Trial Design Suitable for Therapeutic Cancer Vaccine Development? A Recommendation for Alternative Design

Purpose: Phase I clinical trials are generally conducted to identify themaximum tolerated dose (MTD) or the biologically active dose (BAD) using a traditional dose-escalation design. This designmaynot be applied to cancer vaccines, given their unique mechanism of action. The FDA recently published "Guidance for Industry: Clinical Considerations for Therapeutic Cancer Vaccines." However, many qu...

متن کامل

A statistical evaluation of dose expansion cohorts in phase I clinical trials.

BACKGROUND Phase I trials often include a dose expansion cohort (DEC), in which additional patients are treated at the estimated maximum tolerated dose (MTD) after dose escalation, with the goal of ensuring that data are available from more than six patients at a single dose level. However, protocols do not always detail how, or even if, the additional toxicity data will be used to reanalyze th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical oncology : official journal of the American Society of Clinical Oncology

دوره 31 31  شماره 

صفحات  -

تاریخ انتشار 2013