Development and Reproducibility of a Computed Tomography–Based Measurement for Upper Body Subcutaneous Neck Fat
نویسندگان
چکیده
BACKGROUND Upper body subcutaneous neck fat (UBSF) is a unique fat depot anatomically separate from visceral abdominal fat that appears to be associated with cardiometabolic risk above and beyond generalized adiposity. We sought to develop a protocol to quantify UBSF using multidetector computed tomography measurements. METHODS AND RESULTS Protocol development was performed in participants from the Framingham Heart Study who had participated in the multidetector computed tomography scanning substudy, consisting of chest scans. Volumetric assessment of UBSF was defined by 40 contiguous 0.625‐mm slices superior to the body of the sternum. The reader manually traced the chest to identify total neck fat. Breast tissue exterior to the chest wall was excluded. Subcutaneous and visceral fat volumes were obtained using standard protocols. Age‐ and sex‐adjusted Pearson correlation coefficients were used to assess the association among UBSF, traditional adiposity measures, and cardiometabolic risk factors. Inter‐ and intrareader reproducibility was assessed using intraclass correlation coefficients. Volumetric assessments were obtained in 92 participants because 8 scans were not readable (51% women; mean age: 59 years [women], 58 years [men]). The mean volume of UBSF was 310 cm3 for women and 345 cm3 for men. Intra‐ and interreader class correlation coefficients were 0.99 and 0.99, respectively. UBSF was correlated with waist circumference (r=0.90), neck circumference (r=0.75), body mass index (r=0.89), subcutaneous adipose tissue (r=0.87), and visceral adipose tissue (r=0.86). CONCLUSIONS UBSF can be quantified reproducibly using computed tomography in a community‐dwelling sample from the Framingham Heart Study.
منابع مشابه
Reproducibility and Repeatability of Computer Tomography-based Measurement of Abdominal Subcutaneous and Visceral Adipose Tissues
Excessive accumulation of abdominal adipose tissue is a widely recognized as a major feature of obesity, and it can be quantified by dual-energy x-ray absorptiometry (DXA). However, in a phantom study, the inter- and intra-instrument reliability of DXA remains unpredictable. Thus, we attempted to determine the precision of estimates from computer tomography-based measurements and analysis with ...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملDevelopment of Computed Tomography Head and Body Phantom for Organ Dosimetry
Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...
متن کاملSubcutaneous Emphysema, Pneumomediastinum and Pneumothorax in a Patient with Dermatomyositis
Introduction:Spontaneous pneumomediastinum, pneumothorax, and subcutaneous emphysema are rare, but serious complications of inflammatory myopathies and occur more commonly in DM than PM. complications of dermatomyositis (DM) and polymyositis (PM), both of which can be fatal. Case Report:A 20-year-old woman was admitted with neck pain, dyspnea, cough, and fever. She had been diagnosed with derma...
متن کاملPneumomediastinum and subcutaneous emphysema: A case report of rare presentations of foreign body aspiration
Background: Pneumomediastinum (PM) is caused by alveolar rapture. If air leak persists, subcutaneous emphysema occurs. The PM and subcutaneous emphysema have various etiologies. Common causes are respiratory tract infections and asthma exacerbations. Rarely, the PM occurs secondary to foreign body aspiration, and the life-threatening complications will occur without proper treatment. Case repo...