Evaluation of the Olympus PK310 automated enzyme immunoassay system.

نویسندگان

  • M Miura
  • Y Fukuyama
  • T Hirano
  • H Matsuzaki
چکیده

In serum, the primary indicator of vitamin D nutritional status is 25-hydroxyvitamin D [25(OH)D], whereas 1,25dihydroxyvitamin D [l,25(OH)2D1 reflects mineral and skeletal homeostasis. Essential for a reliable assay of 1,25(OH)2D in serum is its separation from 25(OH)D, because the latter circulates in a 1000-fold greater concentration and significantly cross-reacts with the receptors used in radioassays of 1,25(OH)2D. Hollis (1) used a “Bond Elut” C18 colunm (Analytichem International, Harbor City, CA) to separate the two in an acetonitrile extract of serum. Selecting the proper C18 column is critical for this type of separation (1). Here we describe a procedure involving use of an “SPEOctadecyl (C18)” column (J.T. Baker Chemicals, Phillipsburg, NJ) to separate 25(OH)D and 1,25(OH)2D before radioassay. To monitor recovery, we added to three 1-mL serum samples 1000 Bq of [3H}25(OH)D, [3H]1,25(OH)2D, and [3H]24,25-dihydroxyvitamin D, respectively. A serum extract prepared as described by Hollis (1) was applied to an SPE-Octadecyl (C 18) column (500 mg in a 3-mL column) that had been successively prewashed with 3 mL of isopropanol, 3 mL of methanol, and 3 mL of water. After applying the sample, we washed the column with 6 mL of water and 6 mL of methanol/water (70/30, by vol), then eluted the 25(OH)D with 10 mL of hexane/methylene chloride (95/5, by vol). Analytical recoveries of tritium-labeled 25(OH)D and 1,25(OH)2D through the entire extraction and separation procedure were 97% (SD 3.3%) and 96% (SD 5.4%), respectively. Similar results were obtained for several batches of SPE-Octadecyl (C18) columns. To remove residual 25(OH)D, Hollis (1) applied an additional wash of hexane/isopropanol (99/1, by vol) before eluting the 1,25(OH)2D. We found that this wash eluted a substantial fraction of 1,25(OH)2D from the SPE-Octadecyl (C18) column, and we omitted this step in our procedure. Consequently we recovered 2.1% (SD 0.7%) of 25(OH)D in the 1,25(OH)2D fraction. This is acceptable because the apparent increase of the 1,25(OH)2D concentration in serum resulting from this recovery, combined with the 0.1% cross-reactivity of 25(OH)D in the thymus receptor assay (2), corresponds to only 0.002% of the 25(OH)D in serum. A small proportion [12.0% (SD 1.4%)] of the 24,25-dihydroxyvitamin D [24,25(OH)2D] was recovered in the 25(OH)D fraction, the remainder in the 1,25(OH)2D fraction. This does not significantly affect the determination of 1,25(OH)2D and 25(OH)D in the serum, because 24,25(OH)2D cross-reacts by only 0.02% with 1,25(OH)2D in the thymus receptor assay (2) and the concentration of 24,25(OH)2D in serum is low compared with that of 25(OH)D. We determined 25(OH)D and 1,25(OH)2D concentrations in 40 patients’ sera, using this extraction procedure and applying a radioimmunoassay and a radioreceptor assay (both from Incstar Corp., Stillwater, MN) to quantify 25(OH)D and 1,25(OH)2D, respectively, in the appropriate column fractions, the solvents having been evaporated (under nitrogen) and the residues dissolved in the buffers supplied by Incstar Corp. Results obtained by HPLC chromatography (3) correlated well for 25(OH)D (range of values = 10-300 nmolIL, r = 0.97, slope = 0.87, intercept = 0.76, and S = 12.8), and 1,25(OH)2D (range of values = 3-240 pmolJL, r = 0.98, slope = 1.06, intercept 1.47, and S = 8.8). Evidently an SPE-Octadecyl (C18) column effectively separates vitamin D metabolites, permitting reliable radioassay of 25(OH)D and 1,25(OH)2D in serum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

SHORT COMMUNICATION Comparisonof aNewSerumTopiramate Immunoassay to Fluorescence Polarization Immunoassay

Topiramate is a newer anticonvulsant used to treat epilepsy, migraines, bipolar disorder, posttraumatic stress, and other conditions. Serum topiramate concentrations are measured to determine optimal levels, address therapeutic failure or drug–drug interactions, and assess compliance. Two high-throughput assays for serum topiramate measurement were compared: the Seradyn fluorescence polarizatio...

متن کامل

Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if ...

متن کامل

Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.

Various automated chemiluminescence immunoassay (CLIA) analyzers for the detection of antibodies to hepatitis C virus (HCV) are now commercially available in clinical laboratories and are replacing conventional enzyme immunoassays. We investigated the performance of four anti-HCV CLIAs (the Architect Anti-HCV assay on the Architect i2000 system, the Vitros Anti-HCV assay on the Vitros ECiQ Immu...

متن کامل

Evaluation of three commercial serological tests with different methodologies to assess Helicobacter pylori infection.

The sera of 142 Helicobacter pylori-positive and 32 H. pylori-negative patients were assessed by a desktop test (QuickVue), an enzyme-linked immunosorbent assay (ELISA) (HM-CAP), and a solid-phase, two-step chemiluminescent enzyme immunoassay (Immulite). These tests yielded sensitivities of 97, 97, and 91% and specificities of 97, 94, and 100%, respectively. In conclusion, the desktop test and ...

متن کامل

High-throughput automated luminescent magnetic particle-based immunoassay to monitor human exposure to pyrethroid insecticides.

We have developed a sensitive, automated, competitive chemiluminescent immunoassay for the detection of 3-phenoxybenzoic acid (3-PBA), a metabolite common to many pyrethroid insecticides. The system uses a competitive hapten-protein conjugate that has been labeled with an acridinium ester as the chemiluminescent probe and secondary antibody-coated paramagnetic particles for the separation. Afte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1989