Changes of oxidative/antioxidative parameters and DNA damage in firefighters wearing personal protective equipment during treadmill walking training
نویسندگان
چکیده
[Purpose] The purpose of this study was to investigate the influence of personal protective equipment on the oxidant/antioxidant parameters and DNA damage in firefighters during training and recovery. [Subjects and Methods] Twelve male nonsmoking volunteer firefighters (35.1 ± 7.2 years) underwent two maximal treadmill training (9 METs, 6 km/h), within 2 weeks, one in regular clothes and one in personal protective equipment weighing 22.1 kg. Blood samples were obtained before, right after, and 40 min after training. Plasma conjugated dienes, total radical trapping antioxidant potential, erythrocytes antioxidant enzymes activities, and leukocyte DNA damage were measured. [Results] Wearing personal protective equipment during treadmill walking training resulted in increases of plasma conjugated dienes, total radical trapping antioxidant potential, and leukocyte DNA resistance to oxidative stress, which were recovered after in 40 min of rest. Erythrocyte antioxidant enzymes activities remained unchanged during the training either with regular clothes or personal protective equipment. [Conclusion] These results suggest that wearing personal protective equipment during firefighting work could induce oxidative stress, which was enough to produce DNA damage in leukocytes.
منابع مشابه
Perceptual and physiological heat strain: examination in firefighters in laboratory- and field-based studies.
Firefighting demands performing heavy muscular work under adverse and potentially dangerous conditions. Although the physiological and psychological responses to simulated firefighting activities have been described, the heat strain has not been characterised using standardised indices of exercise-heat strain. The purpose of the study is to describe the physiological and perceptual strain assoc...
متن کاملComparison of estimated core body temperature measured with the BioHarness and rectal temperature under several heat stress conditions.
Monitoring and measuring core body temperature is important to prevent or minimize physiological strain and cognitive dysfunction for workers such as first responders (e.g., firefighters) and military personnel. The purpose of this study is to compare estimated core body temperature (Tco-est), determined by heart rate (HR) data from a wearable chest strap physiology monitor, to standard rectal ...
متن کاملEffect of base layer materials on physiological and perceptual responses to exercise in personal protective equipment.
Ten men (non-firefighters) completed a 110 min walking/recovery protocol (three 20-min exercise bouts, with recovery periods of 10, 20, and 20 min following successive bouts) in a thermoneutral laboratory while wearing firefighting personal protective equipment over one of four base layers: cotton, modacrylic, wool, and phase change material. There were no significant differences in changes in ...
متن کاملAge-Related Changes in Doxorubicin-Induced Oxidative Damage: Protective and Pretreatment Effects of Short-Term Aerobic Exercise
ABSTRACT Background and Objective: Doxorubicin (DOX) is an effective anticancer drug. It has been shown that a short-term exercise performed prior to DOX-treatment has no effect on cardiotoxicity in young rats. In the present study, old and young rats were evaluated to determine the protective effects of pre-treatment with short-term exercise on D...
متن کاملImpact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain
Wildfire firefighting is an extremely demanding occupation performed under hot environment. The use of personal protective clothing (PPC) is needed to protect subjects from the thermal exposure. However, the additional use of PPC may increase the wildland firefighters' physiological strain, and consequently limit their performance. The aim of this study was to analyze the effect of four differe...
متن کامل