Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques.

نویسندگان

  • Marcus Richter
  • René Schmidt
  • Lutz Claes
  • Wolfhart Puhl
  • Hans-Joachim Wilke
چکیده

STUDY DESIGN Six different techniques for atlantoaxial fixation were biomechanically compared in vitro by nondestructive testing. OBJECTIVE To evaluate the immediate three-dimensional stability of a new atlas claw combined with transarticular screws and alternative techniques for transarticular screw fixation in comparison with established techniques. SUMMARY OF BACKGROUND DATA Posterior transarticular screw fixation in combination with wire-bone graft constructs is frequently used for C1-C2 fixation. Sublaminar wire passage carries the potential risk of neurologic complication. Transarticular screw fixation is technically demanding and, for anatomic reasons, not always feasible. METHODS Six human cervical specimens were loaded nondestructively with pure moments, and unconstrained motion at C1-C2 was measured. The six specimens were instrumented with each of the following fixation techniques: Gallie fixation, transarticular screws and Gallie fixation, transarticular screws, transarticular screws and a new atlas claw, isthmic screws in the axis and the atlas claw, and lateral mass screws in the atlas and isthmic screws in the axis connected with rods. RESULTS The transarticular screws restricted lateral bending and axial rotation best. The three-point fixations (transarticular + Gallie and transarticular + claw) additionally restricted flexion-extension, with lowest values for transarticular screws and the atlas claw. The alternative techniques were not as stable as the three-point fixations, but more stable than the Gallie fixation. CONCLUSIONS Biomechanically, the three-point fixation with transarticular screws and the atlas claw provides a rigid internal fixation that is not dependent on bone graft and sublaminar wiring. In cases wherein transarticular screws are not feasible, the isthmic screws and claw or the lateral mass screws and isthmic screws are biomechanical alternatives with less immediate stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical impact of C2 pedicle screw length in an atlantoaxial fusion construct

BACKGROUND Posterior, atlantoaxial (AA) fusions of the cervical spine may include either standard (26 mm) or short (16 mm) C2 pedicle screws. This manuscript focused on an in vitro biomechanical comparison of standard versus short C2 pedicle screws to perform posterior C1-C2 AA fusions. METHODS Twelve human cadaveric spines underwent C1 lateral mass screw and standard C2 pedicle screw (n = 6)...

متن کامل

Atlantoaxial Fixation—Anterior or Posterior Approach: Critical Review

Atlantoaxial facet joints have been proposed as the center of mobility and also center for instability of the atlantoaxial region. Because of the high mobility of the atlantoaxial (C1-C2) motion segment, fusion rates at this level have been substantially lower than those at the subaxial spine. The success of craniovertebral junction surgery depends on adequate reduction, decompression of cranio...

متن کامل

Biomechanical comparison of C1-C2 posterior arthrodesis techniques.

STUDY DESIGN Biomechanical comparison of 5 atlantoaxial posterior arthrodesis techniques. OBJECTIVE To assess the relative value of different posterior wire constructs when one or two transarticular screws are used. SUMMARY OF BACKGROUND DATA A combination of Gallie or Brooks techniques and 2 posterior transarticular screws has been shown to be effective for atlantoaxial arthrodesis. Anatom...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Atlantoaxial fixation: overview of all techniques.

Over the past century, steady advances have been made in fixating an unstable atlantoaxial complex. Current options for fixation of the atlantoaxial complex include posterior clamps, posterior wiring techniques, C1-C2 transarticular screw fixation, posterior C1 lateral mass screw with C2 pars or pedicle screw fixation, and anterior transoral C1 lateral mass to C2 vertebral body fixation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 27 16  شماره 

صفحات  -

تاریخ انتشار 2002