The Self-Expanding Symetis Acurate Does Not Increase Cerebral Microembolic Load When Compared to the Balloon-Expandable Edwards Sapien Prosthesis: A Transcranial Doppler Study in Patients Undergoing Transapical Aortic Valve Implantation

نویسندگان

  • Gabor Erdoes
  • Christoph Huber
  • Reto Basciani
  • Stefan Stortecky
  • Stephan Windecker
  • Peter Wenaweser
  • Thierry Carrel
  • Balthasar Eberle
  • Lakshmi P. Dasi
چکیده

OBJECTIVES The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. BACKGROUND Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. METHODS Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. RESULTS No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: < 0.001) or post-implantation PI (SA: p = 0.007; ES: < 0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). CONCLUSIONS Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stroke Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study

Background—Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear....

متن کامل

Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study.

BACKGROUND Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear....

متن کامل

Comparison of two valve systems for transapical aortic valve implantation: a propensity score-matched analysis.

OBJECTIVES Several alternative transapical (TA) aortic prostheses for aortic valve implantation (AVI) have recently become available. Data directly comparing the performance of these different TA-AVI valves, however, are sparse. Therefore, we sought to analyse the performance of the better-established balloon-expandable SAPIEN XT™ valve system, and compare it with the recently approved self-exp...

متن کامل

Valve implantations on the move

Transcatheter aortic valve implantation (TAVI) has expanded rapidly since the first procedure in 2002. The first randomised control trial showed non inferiority of TAVI compared with surgical aortic valve replacement (AVR) in high-risk patients with severe aortic valve stenosis (AS) and superiority as compared with conservative management, including balloon valvuloplasty [1]. Since 2012, TAVI h...

متن کامل

Transapical aortic valve implantation using a new self-expandable bioprosthesis (ACURATE TA™): 6-month outcomes.

OBJECTIVES The ACURATE TA(™) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. METHODS The Symetis ACURATE TA(™) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -