Global endometrial ablation in the presence of essure® microinserts.

نویسندگان

  • Diana Aldape
  • Scott G Chudnoff
  • Mark D Levie
چکیده

Abnormal uterine bleeding (AUB) affects 30% of women at some time during their reproductive years and is one of the most common reasons a woman sees a gynecologist. Many women are turning to endometrial ablation to manage their AUB. This article reviews the data relating to the available endometrial ablation techniques performed with hysteroscopic sterilization, and focuses on data from patients who had Essure® (Conceptus, San Carlos, CA) coils placed prior to performance of endometrial ablation. Reviewed specifically are data regarding safety and efficacy of these two procedures when combined. Data submitted to the US Food and Drug Administration for the three devices currently approved are reviewed, as well as all published case series. Articles included were selected based on a PubMed search for endometrial ablation (also using the brand names of the different techniques currently available), hysteroscopic sterilization, and Essure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Follow-up of successful bilateral placement of Essure microinserts with ultrasound.

OBJECTIVE To evaluate the reliability of pelvic X-ray and transvaginal ultrasound to localize Essure microinserts (Conceptus, San Carlos, California) after successful placement in both fallopian tubes 3 months after placement. DESIGN Prospective, observational study. SETTING Gynecology departments at two teaching hospitals. PATIENT(S) One hundred eighty-two patients who underwent hysteros...

متن کامل

Reproducibility of the interpretation of pelvic x-ray 3 months after hysteroscopic sterilization with Essure.

OBJECTIVE To estimate the diagnostic accuracy and the interobserver reproducibility of pelvic x-rays in the diagnosis of successful bilateral sterilization with Essure after a 3-month follow-up period. DESIGN Interobserver study. SETTING Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. PATIENT(S) Patients with successful bilateral Essure placement. INTERV...

متن کامل

Transcervical Migration of an Essure® Coil

Introduction: Essure® device malposition is a rare, but clinically significant complication, for which management is idiosyncratic. This case report describes an unusual example of Essure® migration in order to clarify reasonable management options. Case Presentation: A 50-year old G4P2022 underwent hysteroscopi...

متن کامل

Evaluation of tubal microinserts position using 3D ultrasound and pelvic X-ray.

PURPOSE To retrospectively compare three-dimensional ultrasonography (3D-US) and pelvic X-rays to assess the position of tubal sterilization microinserts. MATERIAL AND METHODS Forty-four patients who underwent tubal sterilization with Essure(®) microinserts in our institution were included. The microinserts'position was evaluated three months after the procedure using 3D-US and pelvic X-rays....

متن کامل

CLINICAL EFFICACY OF HYSTEROSCOPIC ENDOMETRI AL ABLATION AND FACTORS AFFECTING ITS SUCCESS

In order to assess the efficacy of hysteroscopic endometrial ablation and factors which are important in it's success, a prospective, randomized study was performed in Shiraz university hospitals between Sep. 1995 to Feb. 1998. 50 patients with chief complaints of menorrhagia that were in reproductive age (25- 50 years) and had shown no response to medication and D&C underwent endometrial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Reviews in obstetrics & gynecology

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2013