Stereotactic breast biopsy: indications and results.
نویسندگان
چکیده
Imaging-guided breast biopsy performed with large-core needles can accurately diagnose most breast pathologies, often allowing a diagnosis to be made more quickly and less expensively than with surgical biopsy. Major complications, such as hemorrhage and infection, are extremely rare, although post-biopsy ecchymosis and tenderness are not unusual. Because less tissue is removed, post-biopsy cosmetic deformity does not occur. Stereotactic biopsy is performed by triangulating the position of a breast lesion and by obtaining views angled equally off a central axis. This can be done using dedicated tables or add-on equipment. Stereotactic core biopsy has a reported accuracy of at least 90%. All lesions for which biopsy would ordinarily be recommended are amenable to stereotactic techniques, but those near the chest wall or in the axilla may be more difficult to biopsy with some equipment. Lesions characterized by calcifications are sometimes more difficult to sample. A biopsy diagnosis of ductal atypia, because of its histologic heterogeneity, requires surgical excision to exclude coexistent carcinoma, which has been found in half of women at subsequent surgical excision. A core biopsy diagnosis of ductal carcinoma in situ does not preclude the discovery of invasive carcinoma at surgery. In rare instances, the small tissue volume removed at stereotactic biopsy does not permit a final diagnosis to be made; this occurs most commonly when differentiating phyllodes tumor from fibroadenoma.
منابع مشابه
Step - by - step of ultrasound - guided core - needle biopsy of the breast : review and technique *
The most consistent indications for USguided CB of breast are listed on Table 1. Patients with imaging studies revealing findings as BI-RADS category 4 (approximately 20% to 40% are malignant) or BI-RADS 5 (about 95% are malignant) must undergo biopsy. Findings classified as BI-RADS 3 present a lower risk for malignancy (< 2.0%), but such findings do require short-term follow-up. In such catego...
متن کاملBreast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy
PURPOSE The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. METHODS AND MATERIALS Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammograp...
متن کاملComparison of stereotactic core breast biopsy and open surgical biopsy results at a tertiary care hospital in Pakistan
BACKGROUND The purpose of this study was to determine the yield of stereotactic core breast biopsy and its cost-saving potential. METHODS This observational study was conducted at the Department of Radiology at Aga Khan Hospital in Karachi. All female patients (n = 84) undergoing stereotactic core breast biopsy under mammographic guidance from January 2005 to May 2010 were included. Stereotac...
متن کاملInitial Experience with a Cone-beam Breast Computed Tomography-guided Biopsy System
OBJECTIVE To evaluate our initial experience with a cone-beam breast computed tomography (BCT)-guided breast biopsy system for lesion retrieval in phantom studies for use with a cone-beam BCT imaging system. MATERIALS AND METHODS Under the Institutional Review Board approval, a phantom biopsy study was performed using a dedicated BCT-guided biopsy system. Fifteen biopsies were performed on ea...
متن کاملA comparison of spring-loaded and vacuum-assisted techniques for stereotactic breast biopsy of impalpable microcalcification lesions: experience at Chang Gung Memorial Hospital at Linkou.
BACKGROUND The aim of this study was to assess the diagnostic performance of stereotactic core needle breast biopsy using spring-loaded or vacuum-assisted techniques for impalpable microcalcification lesions in Taiwanese women. METHODS We retrospectively reviewed the data of patients who received stereotactic core needle breast biopsy for impalpable mammographic microcalcification lesions fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Oncology
دوره 12 6 شماره
صفحات -
تاریخ انتشار 1998