چکیده

PURPOSE To measure the rigidity coefficient of a large number of subjects at clinically encountered intraocular pressures (IOPs) and to examine the possible correlation of ocular rigidity with other factors, such as the age of the patients, ocular parameters (axial length and corneal thickness), and pathologic conditions affecting the eye. METHODS The pressure-volume relationship and the ocular rigidity coefficient (K) were determined in 79 eyes undergoing cataract surgery, by injecting 200 microL of saline solution (in steps of 4.5 microL) through the limbus into the anterior chamber, while continually monitoring the IOP with a transducer, up to the limit of 60 mm Hg. Data within an IOP range of 10 to 35 mm Hg were used to calculate the scleral rigidity coefficient. All measurements were taken at the same time of day, to eliminate any possible diurnal variation. RESULTS The mean ocular rigidity coefficient was 0.0126 mm Hg/microL (95% confidence interval [CI], 0.0112-0.0149). A statistically significant positive correlation between the rigidity coefficient and age of the patient was found (P = 0.02), whereas similar findings were not observed for the examined ocular parameters (axial length, P = 0.09; and corneal thickness, P = 0.12). No correlation was found for patients with diabetes mellitus (P = 0.39), age-related macular degeneration (P = 0.55), and hypertension (P = 0.45). CONCLUSIONS The present study provides quantitative data on the ocular rigidity coefficient based on measurements in a large series of living human eyes. A positive correlation between the ocular rigidity coefficient and the patient's age was documented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distensibility of the human eye.

TiE relationship between changes in pressure and changes in volume within the eye is of practical importance in the calibration of tonometers and in tonographic calculations, and the coefficient of ocular rigidity, K, proposed by Friedenwald (1937) has been employed generally for these purposes. Contrary to Friedenwald's assertion, it has been found that this coefficient is not a constant, but ...

متن کامل

Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of intraocular pressure.

PURPOSE The purpose of this study was to characterize the pressure-volume relation in the living human eye, measure the ocular pulse amplitude (OPA), and calculate the corresponding pulsatile ocular blood flow (POBF) in a range of clinically relevant IOP levels. METHODS Fifty patients with cataract (50 eyes) were enrolled in the study. After cannulation of the anterior chamber, a computer-con...

متن کامل

Ocular rigidity evaluation after photorefractive keratectomy: an experimental study.

PURPOSE To evaluate possible changes of the ocular rigidity coefficient in vivo after photorefractive keratectomy (PRK) in a series of rabbit eyes, using an invasive ocular rigidity measurement device. METHODS Sixteen eyes of 8 rabbits were used in this study. One eye from each rabbit underwent PRK for -10.00 diopters (D) in a 5-mm optical zone (92 microm) while the fellow eye served as the c...

متن کامل

Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.

INTRODUCTION A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. METHODS Ten non-pigmented female rabbits were examine...

متن کامل

Studies in Ocular Rigidity.

RECENT developments in tonography and applanation tonometry have caused greater attention to be focused on the relation of the elastic properties of the coats of the eye and of ocular rigidity to the intra-ocular pressure. It is now fairly well established that the coefficient of ocular rigidity, K, is not a constant, as Friedenwald (1937) had suggested, but that it varies with the intra-ocular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 2005