Echocardiographic features in spontaneous disruption of implanted tissue aortic valves.
نویسندگان
چکیده
The echocardiographic features were recorded in three patients with spontaneous disruption of implanted tissue aortic valves. Two of the patients had xenografts, and one had a homograft. Aortic regurgitation had developed in all three spontaneously in the absence of active infective endocarditis. In each case there was severe disruption of the valve. Similar echocardiographic features have been found, usually in association with infective endocarditis or with myxomatous degeneration of the aortic valve. They have not previously been reported in association with implanted tissue aortic valves.
منابع مشابه
مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملEchocardiographic Profile of Normaly Functioning TTK Chitra Tilting Disc Prosthetic Valves
Background and aim of the study: TTK Chitra is a tilting disc prosthetic cardiac valve being used in India. We present the echocardiographic and Doppler evaluation of normally functioning valve in mitral and aortic positions. Methods: A total of 120 patients with 134 valves implanted in the aortic and/or mitral position were studied. All patients underwent a detailed echocardiographic and Doppl...
متن کاملTissue engineered aortic valve
Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation h...
متن کاملNormal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 51 3 شماره
صفحات -
تاریخ انتشار 1984