Systematic assessment of microneedle injection into the mouse cornea

نویسندگان

  • Mario Matthaei
  • Huan Meng
  • Imran Bhutto
  • Qingguo Xu
  • Edwin Boelke
  • Justin Hanes
  • Albert S Jun
چکیده

BACKGROUND Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. METHODS Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. RESULTS A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. CONCLUSIONS Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Permeation of antigen protein-conjugated nanoparticles and live bacteria through microneedle-treated mouse skin

BACKGROUND The present study was designed to evaluate the extent to which pretreatment with microneedles can enhance skin permeation of nanoparticles in vitro and in vivo. Permeation of live bacteria, which are physically nanoparticles or microparticles, through mouse skin pretreated with microneedles was also studied to evaluate the potential risk of microbial infection. METHODS AND RESULTS ...

متن کامل

Keratoconus experimentally produced in mice using collagenase

Introduction: Keratoconus is a relatively common disease of cornea in which structural changes within the cornea cause it to thin and change to a conical shape and scar at the central portion of cornea. So far, few methods and drug treatments were introduced due to both lack of accepted animal models to induce experimental keratoconus and limitation of research in human considering ethical issu...

متن کامل

Coated microneedles for drug delivery to the eye.

PURPOSE To test the hypothesis that coated microneedles can deliver drugs into the eye via intrascleral and intracorneal routes in a minimally invasive manner. METHODS Solid metal microneedles measuring 500 to 750 microm in length were coated with model drugs, protein, and DNA; inserted into nonpreserved human cadaveric sclera; and imaged. Microneedles coated with sodium fluorescein were then...

متن کامل

Design, modelling and preliminary characterisation of microneedle-based electrodes for tissue electroporation in vivo

We analysed the use of microneedle-based electrodes to enhance electroporation of mouse testis with DNA vectors for production of transgenic mice. Different microneedle formats were developed and tested, and we ultimately used electrodes based on arrays of 500 μm tall microneedles. In a series of experiments involving injection of a DNA vector expressing Green Fluorescent Protein (GFP) and elec...

متن کامل

Cigarette Smoking and Pachymetry and Specular Microscopy Parameters of Cornea; A Systematic Review and Meta-analysis

Purpose: To investigate the effect of smoking on corneal parameters, including Endothelial Cell Density, Central Corneal Thickness, Percent of Hexogonality, and Coefficient of Variation. Methods: This study was a systematic review and meta-analysis of published articles until the end of February 2019. To do this, the first search was done for creditable medical databases such as PubMed, and ISI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2012