Long-term reliability of sweet-tip type screw-in leads
نویسندگان
چکیده
BACKGROUND Active fixation leads have provided stable atrial and ventricular pacing; however, long-term follow-up data have not been satisfactory. The purpose of this study was to investigate the long-term reliability of active fixation leads and their electrical characteristic stability. METHODS A total of 1196 pacing leads were implanted in 830 patients consecutively between 2002 and 2013. In this retrospective study, we were able to trace 1092 leads in 750 patients to investigate the prognosis of implanted leads. The measurement values (including pacing thresholds, sensing amplitudes, and lead impedances of both the atrial and ventricular leads) were obtained from medical records at the time of implantation and during follow up at the outpatient device clinic. All pacing leads were FINELINE II Sterox EZ Leads (Boston Scientific, MN, USA), which are sweet-tip type screw-in active fixation leads, except for the shock leads in patients with implantable cardioverter defibrillator. RESULTS The mean follow-up period was 51.3±29.2 months (median, 48 months). A total of 1092 leads were implanted in either the atrium (682 leads) or the ventricle (410 leads). Venous access was achieved through cephalic vein cut down (CVC) method (914 leads) or the subclavian vein puncture (SVP) method (178 leads). The overall lead survival rate was 99.6% at both 5 and 10 years. Lead fracture was observed in 4 of 1092 leads (0.37%), all of which were implanted by the SVP method. No lead fracture occurred among patients wherein CVC method was applied (p<0.01). Device-related infection was observed in four patients (0.53%). CONCLUSIONS The overall reliability and stability of sweet-tip type screw-in leads were satisfactory throughout the long-term follow-up period (median, 4 years). Because it was associated with less lead fractures, cut-down access from the cephalic vein may be recommended as the first-line approach when considering the importance of long-term durability of pacing leads.
منابع مشابه
Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value
Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...
متن کاملLong-term Planning of Optimal Placement of Distribution Transformers to Improve Reliability and Power Quality with the Approach of Reducing Costs and Losses
One of the most critical and complex issues in long-term planning of distribution networks is the optimal placement of distribution transformers. In this paper, the optimal placement of distribution transformers was investigated based on a complete and multi-objective function. In the proposed method, location, optimal capacity, and the service area are determined by minimizing costs (investmen...
متن کاملBiomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation
OBJECTIVE The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. METHODS We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm ...
متن کاملLong-Term Institutional Investors and social
the investment horizons of institutional investors can affect monitoring incentives which might ultimately make an impact on firm CSR decisions. Hence, this paper investigates the effects of institutional investor’s investment horizons on CSR activities.This research has been carried out using annual data of companies accepted in Tehran Stock Exchange during the period of 2011-2018. By screenin...
متن کاملLong-term Results of Osteoarticular Allograft Reconstruction in Children with Distal Femoral Bone Tumors
Background: There is no consensus regarding the best method of reconstruction in pediatric population following thewide resection of malignant bone tumors. More exploration of the complications of osteoarticular reconstruction leads toless existing controversy of this type of reconstruction, which is the main point of this article.Methods: Long-term outcomes and complications of osteoarticular ...
متن کامل