Responsiveness Comparison of the EQ-5D, PROMIS Global Health, and VR-12 Questionnaires in Knee Arthroscopy
نویسندگان
چکیده
BACKGROUND The EuroQol 5 dimensions questionnaire (EQ-5D), Patient-Reported Outcomes Measurement Information System (PROMIS) 10 Global Health, and Veterans RAND 12-Item Health Survey (VR-12) are generic patient-reported outcome (PRO) questionnaires that assess a patient's general health. In choosing a PRO to track general health status, it is necessary to consider which measure will be the most responsive to change after treatment. To date, no studies exist comparing responsiveness among the EQ-5D, PROMIS 10 Global Health, and the Veterans Rand 12-Item Health Survey (VR-12). PURPOSE To determine which of the generic PROs are most responsive internally and externally in the setting of knee arthroscopy. STUDY DESIGN Cohort study (diagnosis); Level of evidence, 3. METHODS Fifty patients who underwent knee arthroscopy were surveyed preoperatively and a mean 3.6 months postoperatively, with 90% follow-up. PROs included the EQ-5D, EQ-5D visual analog scale, PROMIS 10 Global Health (PROMIS 10) physical and mental components, VR-12 physical and mental components, and the Knee injury and Osteoarthritis Outcome Score (KOOS)-pain subscale. Internal responsiveness was evaluated by performing paired t tests on the changes in measures and calculating 2 measures of effect size: Cohen d and standardized response mean (SRM). External responsiveness was evaluated by comparing Pearson correlation measures between the disease-specific reference KOOS-pain and generic PROs. RESULTS For internal responsiveness, 3 PROs showed a statistically significant improvement in score after treatment (EQ-5D: +0.10 [95% CI, 0.06-0.15], VR-12 physical: +7.2 [95% CI, 4.0-10.4]), and PROMIS 10 physical: +4.4 [95% CI, 2.6-6.3]) and effect size statistics with moderate change (Cohen d and SRM, 0.5-0.8). Assessing external responsiveness, a high correlation with the disease-specific reference (KOOS-pain score) was found for EQ-5D (0.65), VR-12 physical (0.57), and PROMIS 10 physical (0.77). For both internal and external responsiveness, the EQ-5D, VR-12 physical, and PROMIS 10 physical showed significantly greater responsiveness compared with the other general PRO measures but no statistical differences among themselves. CONCLUSION There is no statistical difference in internal or external responsiveness to change among the EQ-5D, VR-12 physical, and PROMIS 10 physical instruments. In tracking longitudinal patient health, researchers and administrators have the flexibility to choose any of the general PROs among the EQ-5D, VR-12 physical, and PROMIS 10 physical. We recommend that any study tracking PROs in knee arthroscopy include 1 of these generic instruments.
منابع مشابه
A Comparison of Iran and UK EQ-5D-3L Value Sets Based on Visual Analogue Scale
Background Preference weights for EQ-5D-3L based on visual analogue scale (VAS) has recently been developed in Iran. The aim of the current study was to compare performance of this value set against the UK VAS-based value set. Methods The mean scores for all possible 243 health states were compared using Student t test. Absolute agreement and consistency were investigated using concordance co...
متن کاملMeasuring health-related quality of life in chronic obstructive pulmonary disease: properties of the EQ-5D-5L and PROMIS-43 short form
BACKGROUND The Patient Reported Outcomes Measurement Information System 43-item short form (PROMIS-43) and the five-level EQ-5D (EQ-5D-5L) are recently developed measures of health-related quality of life (HRQL) that have potentially broad application in evaluating treatments and capturing burden of respiratory-related diseases. The aims of this study were: (1) to examine their psychometric pro...
متن کاملValidity and responsiveness of EuroQol-5 dimension (EQ-5D) versus Short Form-6 dimension (SF-6D) questionnaire in chronic pain
BACKGROUND Assessments of health-related quality of life and particularly utility values are important components of health economic analyses. Several instruments have been developed to measure utilities. However no consensus has emerged regarding the most appropriate instrument within a therapeutic area such as chronic pain. The study compared two instruments - EQ-5D and SF-6D - for their perf...
متن کاملInequalities in Health Status from EQ-5D Findings: A Cross-Sectional Study in Low-Income Communities of Bangladesh
Background Measuring health status by using standardized and validated instrument has become a growing concern over the past few decades throughout the developed and developing countries. The aim of the study was to investigate the overall self-reported health status along with potential inequalities by using EuroQol 5 dimensions (EQ-5D) instrument among low-income people of Bangladesh. Metho...
متن کاملComparison of Blood Transfusion Plus Chelation Therapy and Bone Marrow Transplantation in Patients with β-Thalassemia: Application of SF-36, EQ-5D, and Visual Analogue Scale Measures
Background β-Thalassemia is a prevalent genetic disease in Mediterranean countries. The most common treatments for this disease are blood transfusion plus iron chelation (BTIC) therapy and bone marrow transplantation (BMT). Patients using these procedures experience different health-related quality of life (HRQoL). The purpose of the present study was to measure HRQoL in these patients using 2 ...
متن کامل