Validation of volume-pressure recording tail-cuff blood pressure measurements.

نویسندگان

  • Minjie Feng
  • Steven Whitesall
  • Yunyu Zhang
  • Martin Beibel
  • Louis D'Alecy
  • Keith DiPetrillo
چکیده

BACKGROUND The American Heart Association has recommended tail-cuff blood pressure measurement for high-throughput experimental designs, including mutagenesis screens and genetic crosses. However, some tail-cuff methods show good agreement with radiotelemetry and others do not, indicating that each tail-cuff method requires independent validation. METHODS We validated the volume-pressure recording (VPR) tail-cuff method by comparison to simultaneous radiotelemetry measurements. RESULTS Bland-Altman analysis of 560 cycles from 26 independent measurement sessions showed good agreement between VPR and radiotelemetry measurements, with tail-cuff measurements being 0.25 mm Hg lower than telemetry measurements on average. However, the VPR method was less accurate, compared to radiotelemetry, at extreme high and low (i.e., <110 or >180 mm Hg) systolic blood pressures (SBPs). CONCLUSIONS We conclude that the VPR tail-cuff method provides accurate blood pressure measurements over the physiological range of blood pressure in mice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method

The CODA 8-Channel High Throughput Non-Invasive Blood Pressure system measures the blood pressure in up to 8 mice or rats simultaneously. The CODA tail-cuff system uses Volume Pressure Recording (VPR) to measure the blood pressure by determining the tail blood volume. A specially designed differential pressure transducer and an occlusion tail-cuff measure the total blood volume in the tail with...

متن کامل

Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods.

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurement...

متن کامل

Methods for assessing blood pressure values in humans.

In clinical medicine and epidemiology, measurements of blood pressure largely rely upon the use of cuff inflation and Korotkoff sounds. Although still the most practical, this method has been recognized to have important limitations. This paper focuses on two limitations of the cuff method that have been found while recording 24-hour intraarterial blood pressure in free-living normotensive and ...

متن کامل

Telemetric Blood Pressure Assessment in Angiotensin II-Infused ApoE-/- Mice: 28 Day Natural History and Comparison to Tail-Cuff Measurements

Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have...

متن کامل

Validation in awake rats of a tail-cuff method for measuring systolic pressure.

Bu~~AG, RUBEN D. Validation in awake rats of a tail-cuf method for measuring systolic pressure. J. Appl. Physiol. 34(2) : 279-282. 1973. -To determine why results of recent studies on applicability of the tail-cuff method to awake rats have been conflicting, arterial pressures were measured under various conditions. A Doppler ultrasonic flowmeter was used to detect blood flow changes occurring ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of hypertension

دوره 21 12  شماره 

صفحات  -

تاریخ انتشار 2008