Rapid evaluation of weekly scintillation camera resolution and linearity using the orthogonal tri-hole phantom.

نویسندگان

  • E M Smith
  • K T Hopkins
چکیده

OBJECTIVE Both state and federal regulations require weekly monitoring of the resolution and linearity of the scintillation camera. Several phantoms are available to perform this quality control function. These include the quadrant bar. Bureau of Radiological Health (BRH), and orthogonal-hole (OH) phantoms. Each of these phantoms has either functional or temporal limitations on its use. The orthogonal tri-hole phantom (OTHP) was designed to overcome these limitations. METHODS The OTHP consists of a precision-drilled lead plate sandwiched between two plastic plates. The OTHP has an active area of 15 in. x 20 in. which contains an orthogonal array of three-hole (2.5-mm, 3.0-mm, and 4.0-mm) clusters. Intrinsic and extrinsic images were acquired for the OTHP, OH phantom, BRH phantom and quadrant bar phantom. RESULTS The OTHP test pattern allows resolution, linearity, object shape, and contrast to be evaluated simultaneously, either intrinsically or extrinsically, in a single image over the entire useful field-of-view. CONCLUSION The OTHP provides a more quantitative evaluation of the quality control parameters than any other phantom currently available. The use of the OTHP results in cost savings since both camera and technologist time are reduced because only one image is required instead of the two or four needed for other phantoms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Growth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics

In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1999