Relation between implant/abutment vertical misfit and torque loss of abutment screws.

نویسندگان

  • Gustavo Augusto Seabra Barbosa
  • Sérgio Rocha Bernardes
  • Flávio Domingues das Neves
  • Alfredo Júlio Fernandes Neto
  • Maria da Glória Chiarello de Mattos
  • Ricardo Faria Ribeiro
چکیده

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (alpha=0.05) between the misfit values (29.08 +/- 8.78 microm) and the percentage of detorque (50.71 +/- 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns

The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...

متن کامل

Accuracy combining different brands of implants and abutments

OBJECTIVE To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. STUDY DESIGN Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göte...

متن کامل

بررسی میزان کاهش تورک در اباتمنت‌های کست شونده با آلیاژ کروم کبالت پس از اعمال بارگذاری دوره‌ای

Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading. Materials and Methods: 10 castable abutments were cast in Co-Cr alloy...

متن کامل

ارزیابی میزان از دست دادن گشتاور در اباتمنت‌‌‌های زیرکونیایی MAD/MAM و پیش‌ساخته تیتانیومی

Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian dental journal

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2008