Relationship between platelet count and hemodialysis membranes

نویسندگان

  • Rabih Nasr
  • Chadi Saifan
  • Iskandar Barakat
  • Yorg Al Azzi
  • Ali Naboush
  • Marc Saad
  • Suzanne El Sayegh
چکیده

BACKGROUND One factor associated with poor outcomes in hemodialysis patients is exposure to a foreign membrane. Older membranes are very bioincompatible and increase complement activation, cause leukocytosis by activating circulating factors, which sequesters leukocytes in the lungs, and activates platelets. Recently, newer membranes have been developed that were designed to be more biocompatible. We tested if the different "optiflux" hemodialysis membranes had different effects on platelet levels. METHODS Ninety-nine maintenance hemodialysis patients with no known systemic or hematologic diseases affecting their platelets had blood drawn immediately prior to, 90 minutes into, and immediately following their first hemodialysis session of the week. All patients were dialyzed using a Fresenius Medical Care Optiflux polysulfone membrane F160, F180, or F200 (polysulfone synthetic dialyzer membranes, 1.6 m(2), 1.8 m(2), and 2.0 m(2) surface area, respectively, electron beam sterilized). Platelet counts were measured from each sample by analysis using a CBC analyzer. RESULTS The average age of the patients was 62.7 years; 36 were female and 63 were male. The mean platelet count pre, mid, and post dialysis was 193 (standard deviation ±74.86), 191 (standard deviation ±74.67), and 197 (standard deviation ±79.34) thousand/mm3, respectively, with no statistical differences. CONCLUSION Newer membranes have no significant effect on platelet count. This suggests that they are, in fact, more biocompatible than their predecessors and may explain their association with increased survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in Polysulfone-Based Membranes for Hemodialysis

The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...

متن کامل

Resolution of Dialyzer Membrane-Associated Thrombocytopenia with Use of Cellulose Triacetate Membrane: A Case Report

Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility betwe...

متن کامل

Comparative analysis of the long-term effect of two families of high-flux polysulfone dialysers on platelet count: a retrospective cross-sectional study

INTRODUCTION Thrombocytopenia is a potential complication of hemodialysis (HD), and its occurrence has been described even with highly biocompatible polysulfone (PSf) membranes. Dialysis units routinely monitor platelet (PLT) count at the beginning of HD sessions. However, considering that the long-term effects on PLT count could easily be missed, the prevalence of HD-related thrombocytopenia c...

متن کامل

Regulation of platelet count by erythropoiesis-stimulating agents – iron axis in hemodialysis patients

Higher doses of erythropoiesis-stimulating agents (ESAs) contribute to atherothrombotic cardiovascular disease in hemodialysis (HD) patients. Thrombocytosis is associated with increased mortality in ESA-treated HD patients. We investigated variables affecting platelet count and its variability (platelet count increment [Δplatelet count]) in HD patients. This retrospective longitudinal and obser...

متن کامل

Neutrophil-to-Lymphocyte and Platelet-to-Lymphocyte Ratios in COVID-19 Patients and Control Group and Relationship with Disease Prognosis

Background: The present study aimed to compare the complete blood count (CBC) indices between COVID-19 patients and the control group, and assess the relationship of these indices with COVID-19 prognosis given the role of complete blood counts in the COVID-19 prognosis. Methods: COVID-19 patients (confirmed by PCR or CT-Scan) who visited Imam Hospital in Sari were selected in this case-control...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013