Novel hybrid drilling protocol: evaluation for the implant healing--thermal changes, crestal bone loss, and bone-to-implant contact.
نویسندگان
چکیده
OBJECTIVES To evaluate a new hybrid drilling protocol, by the analysis of thermal changes in vitro, and their effects in the crestal bone loss and bone-to-implant contact in vivo. MATERIALS AND METHODS Temperature changes during simulated osteotomies with a hybrid drilling technique (biologic plus simplified) (test) versus an incremental drilling technique (control) were investigated. One hundred and twenty random osteotomies were performed (60 by group) in pig ribs up to 3.75-mm-diameter drill to a depth of 10 mm. Thermal changes and time were recorded by paired thermocouples. In a parallel experiment, bilateral mandibular premolars P2, P3, P4, and first molar M1 were extracted from six dogs. After 2-month healing, implant sites were randomly prepared using either of the drilling techniques. Forty eight implants of 3.75 mm diameter and 10 mm length were inserted. The dogs were euthanized at 30 and 90 days, and crestal bone loss (CBL) and bone-to-implant contact (BIC) were evaluated. RESULTS The control group showed maximum temperatures of 35.3 °C ± 1.8 °C, ΔT of 10.4 °C, and a mean time of 100 s/procedure; meanwhile, the test group showed maximum temperatures of 36.7 °C ± 1.2 °C, ΔT of 8.1 °C, and a mean time of 240 s/procedure. After 30 days, CBL values for both groups (test: 1.168 ± 0.194 mm; control: 1.181 ± 0.113 mm) and BIC values (test: 43 ± 2.8%; control: 45 ± 1.3%) were similar, without significant differences (P > 0.05). After 90 days, CBL (test: 1.173 ± 0.187 mm; control: 1.205 ± 0.122 mm) and BIC (test: 64 ± 3.3%; control: 64 ± 2.4%) values were similar, without significant differences (P > 0.05). The BIC values were increased at 90 days in both groups compared with the 30-day period (P < 0.05). CONCLUSIONS Within the limitations of this study, the new hybrid protocol for the preparation of the implant bed without irrigation, increase the temperature similarly to the incremental conventional protocol, and requires twice the time for the completion of the drilling procedure in vitro. Crestal bone loss and bone-to-implant contact in the hybrid drilling protocol are comparable with the conventional drilling protocol and do not affect the osseointegration process in vivo.
منابع مشابه
بررسی رادیوگرافیک اثر بارگذاری تدریجی بر روی تغییرات استخوان کرستال و تراکم استخوان اطراف ایمپلنتهای تک واحدی خلف ماگزیلا
Background and Aim: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single crowns by an accurate longitudinal radiographic assessment technique. Materials and Methods: Eleven Micro-Thread Osseo Speed dental implants were place...
متن کاملCrestal bone remodeling around implants placed using a short drilling protocol.
PURPOSE The aim of the study was to examine the influence of a short drilling protocol on peri-implant crestal bone levels. MATERIALS AND METHODS Forty implants were placed in the posterior mandibles of 20 patients. The implants (diameter, 4.2 mm; length, 10 to 11.5 mm) were inserted in pairs: one implant was inserted using the standard drilling protocol (five drills in sequence), while the o...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملمقایسه میزان تحلیل استخوان کرستال اطراف ایمپلنتهای Replace با دو روش Submerge و Non-submerge
Background and Aim: It is well recognized that implant treatment is common worldwide, but the approach to success is not predictable because of bone loss that occurs around the implants. Also there are many factors affecting crestal bone loss around the implants that one of them is the surgical protocol of implant installation. The purpose of this investigation was to evaluate the amount of cre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2015