A Study of Discharge Coefficient in Bileaflet Valves

نویسندگان

  • M. Grigioni
  • C. Daniele
  • G. D'Avenio
  • U. Morbiducci
  • C. Del Gaudio
  • V. Barbaro
چکیده

The measurement of a cardiac valve's area is a common procedure, usually performed with noninvasive, Doppler-based techniques. Such measurements are not, however, without problems: a potential source of errors is the value of a valve’s discharge coefficient. In-vitro pressure and flow measurements relative to the bileaflet valve of four brands were performed. A total of 12 valve samples was studied to cover the entire range of valve sizing. The data were used in the Gorlin formula for valve area measurements, and the dependence of the discharge coefficient on the internal diameter of the valve and the flow rate was accurately determined. The reported results can be used in a great number of follow-up clinical assessments to improve the accuracy of valvular orifice measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.

BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flo...

متن کامل

Antithrombotic Therapy in Patients With Mechanical and Biological Prosthetic Heart Valves

In 1992, based on extensive review of the literature, we concluded that in patients with mechanical prosthetic heart valves,1 (1) long-term (permanent) therapy with oral anticoagulants offers the most consistent protection, and (2) levels of oral anticoagulants that prolong the prothrombin time (PT) ratio to an international normalized ratio (INR) of 2.5 to 3.5 are satisfactory for tilting disk...

متن کامل

Bubbles in the heart.

To the Editor: The image by Catapano et al1 gives misleading information concerning bubbles in the heart in patients with prosthetic valves. They speculated that “bright particles” seen in the left ventricular cavity are consistent with gas bubbles that occur in scuba divers after hypobaric decompression. We disagree with this speculation, because this phenomenon is well documented in patients ...

متن کامل

Elliptic st. jude bileaflet mechanical heart valves

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977. The SJM valve design consists of two semicircular leaflets which pivot on hinges. Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the v...

متن کامل

The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

BACKGROUND AND OBJECTIVES The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS In 20 patients (mean age, 50+/-12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001