Fusion of real-time 3D transesophageal echocardiography and cardiac fluoroscopy imaging in transapical catheter-based mitral paravalvular leak closure

نویسندگان

  • Aleksejus Zorinas
  • Vilius Janusauskas
  • Giedrius Davidavicius
  • Lina Puodziukaite
  • Diana Zakarkaite
  • Rita Kramena
  • Rasa Čypienė
  • Valdas Bilkis
  • Kestutis Rucinskas
  • Audrius Aidietis
  • Eustaquio M. Onorato
چکیده

Corresponding author: Aleksejus Zorinas, Heart Surgery Centre, Vilnius University Hospital Santariskiu Klinikos, Santariskiu 2, 08406 Vilnius, Lithuania, phone: +370 52365000, fax: +370 52365111, mobile: +370 698 29079, e-mail: [email protected] Received: 11.04.2017, accepted: 17.06.2017. Fusion of real-time 3D transesophageal echocardiography and cardiac fluoroscopy imaging in transapical catheter-based mitral paravalvular leak closure

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transapical closure of mitral prosthetic paravalvular leak.

Clinically significant mitral prosthetic paravalvular leaks may occur in up to 5% of patients following surgical mitral valve replacement. Successful closure may offer relief from symptoms of heart failure and hemolysis, but surgical closure is associated with increased morbidity and mortality. Alternative transcatheter closure techniques are being developed. We present a patient who was succes...

متن کامل

Tricuspid paravalvular leak closure with a paravalvular leak device

A 69-year-old man, with a permanent pacemaker (PM) and a tricuspid bioprosthesis implanted 6 years ago, was admitted due to gradual exacerbation of heart failure symptoms to NYHA class III. Transthoracic (TTE) and transesophageal (TEE) echocardiography revealed proper function of bioprosthesis leaflets accompanied by the presence of severe paravalvular leak (PVL) with the PM lead crossing its c...

متن کامل

Real-time three-dimensional TEE-guided repair of a paravalvular leak after mitral valve replacement.

Paravalvular leaks are well-known complications seen following cardiac valve surgery. We report a case in which real-time three-dimensional TEE (3D-TEE) was utilized intraoperatively to identify the number, severity, and precise locations of a paravalvular leak at the time of surgery for mitral valve replacement.

متن کامل

Percutaneous closure of paravalvular mitral regurgitation with Vascular Plug III under the guidance of real-time three-dimensional transesophageal echocardiography.

Transcatheter closure of mitral prosthetic paravalvular leak (PVL) has been hampered by technical challenges and the lack of closure devices specifically designed for this purpose. The oblong cross-sectional shape of the Amplatzer Vascular Plug III device (AVP) may be a more appropriate choice to be deployed for mitral PVL's. Real-time three-dimensional transesophageal echocardiography (RT-3D T...

متن کامل

Transapical transcatheter device closure of relapse left ventricular diverticulum: a novel minimally invasive technique for reoperation

We describe a novel minimally invasive technique, transapical transcatheter device closure of relapse left ventricular diverticulum (LVD) under transesophageal echocardiography (TEE) guidance. The patient previously underwent LVD primary repair and mitral valvular replacement. The anatomical characteristics of the relapse LVD and its adjacent structures are detailedly delineated by echocardiogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017