Awake intubation using fast-track laryngeal mask airway as an alternative to fiberoptic bronchoscopy: a case report.
نویسندگان
چکیده
Patients with rheumatoid arthritis (RA) pose a unique challenge to the anesthetist. The manifestations of RA may include cervical spine instability, limited range of motion, and temperomandibular joint involvement limiting mouth opening. Therefore, securing the airway while maintaining the head and neck in a neutral position is of particular concern to the anesthetist. While this is most commonly accomplished using an awake fiberoptic technique, the following case is presented as a safe and efficient initial alternative to the primary use of fiberoptic bronchoscopy in the appropriate patient population.
منابع مشابه
Awake intubation with video-assisted laryngoscope or intubating stylet
Corresponding author: Jin-Kyoung Kim, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Gangnam-gu, Seoul 135-710, Korea. Tel: 82-2-3410-2477, Fax: 82-2-3410-6626, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial L...
متن کاملCorrection to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report
Correction to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report Hooshang Akbari1, Ravanbakhsh Esmaeili2 1 Assistant Professor, Department of Anesthesiology, Faculty of Paramedical, Mazandaran University of Medical Sciences, Sari, Iran 2 Assistant Professor, Department of Medical Surgical Nursing...
متن کاملConscious Sedation and Awake Fiberoptic Intubation in a Patient with Difficult Mask Ventilation—A Case Report
Since maxillofacial malignancy is a common cause of facial defects and disfigurement of the face that may make fitting of a mask difficult and cause air leakage from the side, thus making mask ventilation difficult. In addition, distorted anatomy of the airway and base of the skull in such patients may cause difficult intubation (DI). We experienced a case with a huge facial defect due to maxil...
متن کامل[Difficult fiberoptic tracheal intubation in 1 month-old infant with Treacher Collins Syndrome].
Neonates and small infants with craniofacial malformation may be very difficult or impossible to mask ventilate or intubate. We would like to report the fiberoptic intubation of a small infant with Treacher Collins Syndrome using the technique described by Ellis et al. CASE REPORT An one month-old infant with Treacher Collins Syndrome was scheduled for mandibular surgery under general endotra...
متن کاملAwake Glidescope® intubation in patients with severe arytenoid swelling after laryngeal surgery with radiation therapy
provided the original work is properly cited. CC General anesthesia in patients who have previously undergone supracricoid partial laryngectomy (SCPL) and radiation therapy for laryngeal cancer is not common but a challenging task for anesthesiologists because of the distortion of the airway anatomy with stiff neck. A 42-year-old (171 cm, 73 kg) man was scheduled for insertion of a percutaneous...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AANA journal
دوره 74 6 شماره
صفحات -
تاریخ انتشار 2006