Ziehl-neelsen Microscopy in the Diagnosis of Tuberculosis in Settings of High Human Immunodeficiency Virus Prevalence.

نویسندگان

  • H D N Nyamogoba
  • G Kikuvi
  • S Mpoke
  • P G Waiyaki
  • D Van Soolingen
چکیده

OBJECTIVE To determine the accuracy of Ziehl-Neelsen microscopy in the diagnosis of TB in setings of high HIV prevalence. DESIGN Cross-sectional descriptive study. SETTING Hospitals serving areas of high human immunodeficiency virus prevalence in western Kenya. The study was conducted between September 2007 and September 2009. RESULTS In total, 341/872(39.1%) of the TB suspects were positive in ZN, 53.1% (181/341) of them culture positive. Only 3.8% (20/531) of the ZN smear negatives were culture positive. Of the 695 suspects evaluated for both Mycobacterium and HIV infection, 255 (36.7%) were ZN smear positive, 42.7% of them HIV positive. Out of the 440 ZN smear negatives, 37% were HIV positive. Similarly, 168 suspects were culture positive, 46.4% of them HIV positive. The HIV infection did not significantly reduce ZN smear positivity rate (P = 0.42) and culture sensitivity (P = 0.09). The ZN sensitivity and specificity were 88.1% and 79.7%, respectively. The predictive values were 58.0 (PPV), and 95.5% (NPV), respectively. However, the area under the ROC curve was 0.84, with 95% CI between 0.80-0.87 and P < 0.001). The ZN smear microscopy had a lesser ability to distinguish between TB and non-TB cases compared to culture. CONCLUSION ZN microscopy causes a significant over-diagnosis of TB in settings of high HIV/AIDS prevalence. There is need for further studies on this subject taking into consideration the various confounding factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Polymerase Chain Reaction, Ziehl-Neelsen Staining and Histopathologic Findings in Formalin-fixed, Paraffin-Embedded Tissue Specimens for Diagnosis of Tuberculosis

Background and Objective: Tuberculosis is still a major health problem, involving about 1/3 of the world´s population. Diagnosis is difficult when we only use Ziehl-Neelson staining. Many cases may be missed. A more rapid and sensitive diagnostic method is necessary. PCR may be helpful. The aim of this study was to compare PCR, Zieh-Neelsen staining and histopathologic findings in diagnosis of ...

متن کامل

Agreement between Direct Fluorescent Microscopy and Ziehl-Neelsen Concentration Techniques in Detection of Pulmonary Tuberculosis in Northwest Ethiopia

Background The sensitivity of smear microscopy for diagnosis of tuberculosis might be improved through treatment of sputum with sodium hypochlorite and application of fluorescent microscopy. This study aimed to determine the agreement between direct Fluorescent Microscopy and Ziehl-Neelsen concentration technique by their ability of detecting acid fast bacilli in resource poor settings. Metho...

متن کامل

Pulmonary infection by Rhodococcus equi presenting with positive Ziehl-Neelsen stain in a patient with human immunodeficiency virus: a case report

INTRODUCTION Patients with human immunodeficiency virus carry a significant risk of contracting opportunistic infections. The worldwide increased incidence of tuberculosis has instituted pulmonary tuberculosis as an important diagnostic consideration in patients with human immunodeficiency virus presenting with lower respiratory tract infection. A positive result on the readily-available Ziehl-...

متن کامل

Comparison of Flurochrome , Ziehl-Neelsen and Tan Thiam Hok Staining Methods for Detection of Mycobacterium tuberculosis in Sputums of Patients with Pulmonary Tuberculosis

Abstract Background and objectives: Direct smear microscopy, because of its simplicity, rapidity, low cost and relatively sensitive is a suitable method to detecting pulmonary tuberculosis. This experiment was aimed at determining the best method for detecting Mycobacterium tuberculosis among three kinds of staining methods: Fluorochrome, Ziehl Neelsen and Tan Thiam Hok . Material and Methods: ...

متن کامل

The CyScope® fluorescence microscope, a reliable tool for tuberculosis diagnosis in resource-limited settings.

Poor laboratory equipment and few human resources have made it difficult to implement microscopic diagnosis of pulmonary tuberculosis (TB) on a large scale basis worldwide. Three hundred sputum samples from patients in Cameroon were studied by using the CyScope®, a new light-emitting, diode-based, fluorescence microscope, to compare auramine-rhodamine fluorescence with the conventional Ziehl-Ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • East African medical journal

دوره 89 8  شماره 

صفحات  -

تاریخ انتشار 2012