Quality assessment model of 3 different microkeratomes through confocal microscopy.

نویسندگان

  • Jaime Javaloy Estañ
  • María T Vidal
  • Antonio Quinto
  • Victoria De Rojas
  • Jorge L Alió
چکیده

PURPOSE To study the quality of the cut created by 3 microkeratomes from 2 different generations using corneal confocal microscopy. SETTING Department of Refractive Surgery, Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS Two different studies were conducted: Study 1 and Study 2. Study 1 was a prospective analysis using confocal microscopy examination data from 2 reference groups: Group A (control) with 20 nonoperated eyes of 20 healthy volunteers, and Group B with 50 eyes of 30 patients operated on with the Bausch & Lomb Automated Corneal Shaper (ACS) microkeratome. Study 2 was a prospective randomized double-masked study in which 40 eyes of 20 patients underwent myopic laser in situ keratomileusis by 1 surgeon. The right and left eyes of each patient were randomly and alternatively assigned to Group C, flap made with the Hansatome microkeratome, or Group D, flap made with the Moria M2. Immediately after surgery, the microscopic appearance of the cut was subjectively evaluated by the surgeon. One month postoperatively, flap thickness, particle density, and the subclinical confocal wound healing opacity (WHO) index were evaluated with the corneal confocal microscope. RESULTS Surgeon handling comfort was nearly the same with the Hansatome as with the M2 (P =.540). However, the apparent quality of the resulting flap was better with the M2 microkeratome (P =.041). The depth of the cuts made by the 3 microkeratomes were significantly different (P<.001), with the ACS flaps being thinner than the flaps made with the Hansatome or the M2. Particle density at the interface was significantly poorer in the eyes operated on with the ACS, but in these cases the WHO index was significantly greater (P<.001 in both cases). CONCLUSIONS Confocal microscopy is a very useful tool to evaluate the quality of the cut made by different microkeratomes. Overall, the predictability in flap thickness and the apparent quality of the cut made by the Moria M2 microkeratome are better than those obtained with the Hansatome or the ACS. The thin flap made by the ACS microkeratome produced a significantly greater WHO index than the thicker flaps created with the other 2 microkeratomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative assessment of corneal wound healing following IntraLASIK using in vivo confocal microscopy.

PURPOSE To compare the response of the cornea to laser in situ keratomileusis (LASIK) with flap creation using the IntraLase FS15, FS30, and FS60 femtosecond lasers. METHODS A retrospective analysis of 55 patients (55 eyes) who underwent LASIK with flap creation using IntraLase was performed. Twelve FS15 patients (12 eyes), 14 FS30 patients (14 eyes), and 29 FS60 patients (29 eyes) were exami...

متن کامل

Cut edges and surface characteristics produced by different microkeratomes.

PURPOSE To determine the cutting characteristics of seven different microkeratomes and to compare the cut edges and surface characteristics of the corneas with respect to different keratome parameters, ie, blade oscillation frequencies and keratome speed. METHODS Lamellar keratectomies were performed using each microkeratome on eight freshly enucleated porcine corneas. The freshly cut corneal...

متن کامل

Morphology of the stromal surface and endothelium using two different microkeratomes.

PURPOSE To compare stromal surface and endothelial morphology after keratectomies and after laser in situ keratomileusis (LASIK), using two different microkeratomes. METHODS Keratectomies (160-microm and 400-microm) were performed on 82 enucleated porcine eyes using the Chiron Automated Corneal Shaper (52 eyes) and the Microtech Turbokeratome (30 eyes). LASIK procedures of -9.00 D, -27.00 D, ...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Comparison of two microkeratome systems.

BACKGROUND Microkeratomes are currently used for keratomiluesis in situ (automated lamellar keratoplasty) for myopia and hyperopia and for laser in situ keratomileusis (LASIK). Visual and refractive complications have been reported with these refractive surgical procedures. We compared two microkeratomes in their ability to resect corneal lamellae to gain insight into possible mechanism(s) of r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2004