Evaluation of high-resolution CT and MR cisternography in the diagnosis of cerebrospinal fluid fistula.

نویسندگان

  • P G Shetty
  • M M Shroff
  • D V Sahani
  • M V Kirtane
چکیده

PURPOSE We undertook this study to determine the accuracy of MR cisternography and plain high-resolution CT as a noninvasive alternative to CT cisternography in the diagnosis of CSF fistula in patients with clinically suspected CSF rhinorrhea. METHODS Forty-five consecutive patients with clinically suspected CSF rhinorrhea were examined prospectively for CSF fistula with MR cisternography and plain high-resolution CT. Twenty-one patients also underwent CT cisternography. The MR imaging technique included 3-mm thin-section T1-weighted coronal sequences and fast spin-echo T2-weighted coronal, axial, and sagittal sequences in the supine position. The plain high-resolution CT study included 3-mm and sometimes 1- to 1.5-mm thin coronal sections in the prone position. Similar sequences were used after injecting nonionic contrast material intrathecally via lumbar puncture for the CT cisternographic study. The plain high-resolution CT and MR cisternographic studies were compared with results of CT cisternography; surgical findings were used as the standard of reference. RESULTS Plain high-resolution CT successfully depicted the presence or absence of CSF fistula in 42 of 45 patients, whereas MR cisternography was correct in 40 patients. MR cisternography or plain high-resolution CT correctly showed the site(s) of CSF fistula leakage in 36 of the 38 cases proved surgically. The combined techniques also correctly indicated the absence of CSF leakage in seven cases, six of which were confirmed at CT cisternography. Both MR cisternography and high-resolution CT failed to definitively locate the CSF fistula in two patients. High-resolution CT was accurate in 93% of patients, whereas MR cisternography was accurate in 89% of patients. The combination of high-resolution CT and MR cisternography was accurate in 96% of patients. CONCLUSION In the presence of clinically diagnosed CSF leakage, the combination of MR cisternography and plain high-resolution CT is highly accurate in locating the site and extent of CSF fistula and should be considered a viable noninvasive alternative to CT cisternography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Invasive and Minimally Invasive Imaging Evaluation of CSF Rhinorrhoea – a Retrospective Study with Review of Literature

BACKGROUND Localization of a cerebrospinal fluid [CSF] fistula is a diagnostic challenge. The choice of an optimal imaging technique is necessary to locate the site of CSF leak which is required for surgical/endoscopic repair of the CSF fistula. MATERIAL/METHODS Retrospective analysis of imaging was performed in 33 patients who presented with symptoms suggestive of CSF rhinorrhoea over a peri...

متن کامل

Cerebrospinal fluid otorhinorrhea in patients with defects through the lamina cribrosa of the internal auditory canal.

We describe three patients with bilateral cerebrospinal fluid (CSF) otorhinorrhea with unilateral progressive hearing loss in whom CT showed the defect to be located in the lamina cribrosa of the internal auditory canal. CT cisternography showed the CSF fistula in two of the three patients who had Mondini malformation, whereas the CSF fistula was obvious on the plain high-resolution temporal bo...

متن کامل

Endoscopic management of cerebrospinal fluid rhinorrhea from anterior skull base defects

  Abstract   Background: Over the past 20 years, the minimally invasive endoscopic approach   has gained widespread acceptance. The study was performed to evaluate the   diagnostic method and the success rate of endoscopically diagnosed and treated CSF   rhinorrhea, and also investigations such as leakage site and etiologic factor.   Methods: This retrospective CSF leakage management review of ...

متن کامل

Cerebrospinal fluid fistula: detection with MR cisternography.

PURPOSE Our goal was to assess the role of MR cisternography in the examination of patients with suspected CSF rhinorrhea. METHODS MR cisternography was performed as a heavily T2-weighted fast spin-echo study with fat suppression and video reversal of the images in 37 patients over a 3-year interval. Twenty-four of the patients subsequently had exploratory surgery for fistula. Statistical ana...

متن کامل

Digital subtraction cisternography: a new approach to fistula localisation in cerebrospinal fluid rhinorrhoea.

Positive contrast cisternography with digital subtraction of fluoroscopy images before computed tomography (CT) was employed in the investigation of eight patients with cerebrospinal fluid (CSF) rhinorrhoea. Fistulae were visualised by preliminary digital subtraction cisternography (DSC) in six patients and in five patients the sites of leakage were confirmed at surgery. Fluoroscopy facilitated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 1998