Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.

نویسندگان

  • V Malfroy Camine
  • H A Rüdiger
  • D P Pioletti
  • A Terrier
چکیده

A good primary stability of cementless femoral stems is essential for the long-term success of total hip arthroplasty. Experimental measurement of implant micromotion with linear variable differential transformers is commonly used to assess implant primary stability in pre-clinical testing. But these measurements are often limited to a few distinct points at the interface. New techniques based on micro-computed tomography (micro-CT) have recently been introduced, such as Digital Volume Correlation (DVC) or markers-based approaches. DVC is however limited to measurement around non-metallic implants due to metal-induced imaging artifacts, and markers-based techniques are confined to a small portion of the implant. In this paper, we present a technique based on micro-CT imaging and radiopaque markers to provide the first full-field micromotion measurement at the entire bone-implant interface of a cementless femoral stem implanted in a cadaveric femur. Micromotion was measured during compression and torsion. Over 300 simultaneous measurement points were obtained. Micromotion amplitude ranged from 0 to 24µm in compression and from 0 to 49µm in torsion. Peak micromotion was distal in compression and proximal in torsion. The technique bias was 5.1µm and its repeatability standard deviation was 4µm. The method was thus highly reliable and compared well with results obtained with linear variable differential transformers (LVDTs) reported in the literature. These results indicate that this micro-CT based technique is perfectly relevant to observe local variations in primary stability around metallic implants. Possible applications include pre-clinical testing of implants and validation of patient-specific models for pre-operative planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new technique to measure micromotion distribution around a cementless femoral stem.

The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the...

متن کامل

Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem.

Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to...

متن کامل

Initial Stability of Cementless Femoral Stems: An In Vitro Technique to Measure Micromotion and Gap Around the Loaded Stem

Currently available techniques used to measure experimentally micromotion directly at the bone-implant interface rely on LVDT sensors [2]. They allow a good precision but they also include the bone deformation between the device fixation point and the measurement site. Moreover, the reported maximum number of simultaneous measurement points on bone with sensors was six [3]. Introduction Valérie...

متن کامل

Postoperative Evaluation of the Initial Stability of the Cementless Hip Stem using Patient-specific Finite Element Analysis

INTRODUCTION: The initial stability of a porousor hydroxyapatitecoated cementless stem is important to ensure subsequent osseointegration of the stem and long-term clinical performance. The main reason for the loosening of cementless stems soon after total hip arthroplasty (THA) is a lack of initial implant stability, resulting in micromotion at the bone implant interface. Excessive micromotion...

متن کامل

Simultaneous and multisite measure of micromotion, subsidence and gap to evaluate femoral stem stability.

The initial stability of cementless femoral components is crucial for the long-term success of total hip arthroplasty. This has been reported in animal and clinical studies. Until now, the stability was evaluated by the measurement of relative micromotion on a few simultaneous locations around the stem in cadaveric experiments. This paper presents an extended experimental setup to measure simul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 49 16  شماره 

صفحات  -

تاریخ انتشار 2016