Tandem multipass Fabry-Perot interferometer for Brillouin scattering.
نویسندگان
چکیده
A new design of a plane mirror Fabry-Perot interferometer with the mirror blanks freely supported by horizontal rings is described. Special attention is paid to the surface flatness and dielectric coatings of the mirrors. It is shown that any two piezoelectrically scanned Fabry-Perot interferometers can be synchronized in tandem operation using simple optics and standard electronic driving and stabilization equipment. Applications of the tandem system to Brillouin scattering are given. The observation of Brillouin spectra of supported thin plastic films and of a clamped metal surface is reported.
منابع مشابه
High-extinction VIPA-based Brillouin spectroscopy of turbid biological media
Brillouin microscopy has recently emerged as powerful technique to characterize the mechanical properties of biological tissue, cell and biomaterials. However, the potential of Brillouin microscopy is currently limited to transparent samples, because Brillouin spectrometers do not have sufficient spectral extinction to reject the predominant non-Brillouin scattered light of turbid media. To ove...
متن کاملRayleigh-Brillouin scattering to determine one-dimensional temperature and number density profiles of a gas flow field.
Rayleigh-Brillouin spectra for heated nitrogen gas were measured by imaging the output of a Fabry-Perot interferometer onto a CCD array. The spectra were compared with the theoretical 6-moment model of Rayleigh-Brillouin scattering convolved with the Fabry-Perot instrument function. Estimates of the temperature and a dimensionless parameter proportional to the number density of the gas as funct...
متن کاملHigh-extinction virtually imaged phased array-based Brillouin spectroscopy of turbid biological media
Brillouin microscopy has recently emerged as a powerful technique to characterize the mechanical properties of biological tissue, cell, and biomaterials. However, the potential of Brillouin microscopy is currently limited to transparent samples, because Brillouin spectrometers do not have sufficient spectral extinction to reject the predominant non-Brillouin scattered light of turbid media. To ...
متن کاملEdge technique for direct detection of strain and temperature based on optical time domain reflectometry.
A hybrid technique for real-time direct detection of strain and temperature along a single-mode fiber is proposed. The temperature is directly detected from the Raman backscattering in the time domain. To retrieve the strain profile from the Brillouin backscattering, an edge technique is introduced and a response function of the Fabry-Perot interferometer for the Brillouin backscattering is def...
متن کاملNote: Higher resolution Brillouin spectroscopy by offset stabilization of a tandem Fabry-Pérot interferometer.
A simple modification to a Sandercock-type tandem Fabry-Pérot interferometer is demonstrated. By adding an independent reference laser with temperature tunability, narrow Brillouin lines that are tens GHz shifted from the Rayleigh line can be recorded with much higher frequency resolution than in the original system.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 20 8 شماره
صفحات -
تاریخ انتشار 1981