Shielding in whole brain irradiation in the multileaf collimator era: dosimetric evaluation of coverage using SFOP guidelines against in-house guidelines.
نویسندگان
چکیده
AIM Compare the planning target volume (PTV) coverage in three different shielding techniques in cranial irradiation. SETTINGS AND DESIGN Tertiary care center, prospective study. MATERIALS AND METHODS The whole brain and meninges were contoured in ten planning CT scans, and expanded by 5 mm for the PTV. Shielding was designed using the French Society of Pediatric Oncology (SFOP) guidelines (SFOP plan), in-house recommendation (with 1 cm margin from the orbital roof and sphenoid wing) on a igitally Reconstructed Radiograph (DRR) and a third plan was generated using a 3D conformal radiation technique (3DCRT). The coverage of the PTV was noted using the isodose covering 95% of the PTV(D95), minimum dose within the PTV(D min ), and maximum dose within the PTV(D max ). The location of PTV not covered by the 95% isodose curve was noted. The median dose and maximum dose (D max ) to both eyes and maximum dose D max for the lens were noted. STATISTICAL ANALYSIS General linear model method repeated the measure of analysis of variance test (ANOVA). RESULTS PTV coverage was significantly poorer in the SFOP and in-house plans as compared to 3DCRT plan (P=0.04). Median volume of PTV not covered by 95% isodose curve was 4.18 cc, 1.01 cc, and 0 cc in SFOP, in-house, and 3DCRT plan, respectively. CONCLUSIONS In the absence of volumetric planning techniques, SFOP guidelines lead to inadequate coverage and the in-house method is recommended.
منابع مشابه
The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کاملPhysical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D
Background:Â Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...
متن کاملMonte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...
متن کاملBeam characteristic of P.E collimators Add-on multileaf collimator
Introduction: Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the ...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cancer research and therapeutics
دوره 6 2 شماره
صفحات -
تاریخ انتشار 2010