Measurement of Scleral Thickness in Humans Using Anterior Segment Optical Coherent Tomography
نویسندگان
چکیده
Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-to-posterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- and inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46 μm. Meridian SN was the thinnest (662±57 μm) and I the thickest (806±60 μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4 mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.
منابع مشابه
Analysis of anterior segment dynamics using anterior segment optical coherence tomography before and after laser peripheral iridotomy.
OBJECTIVE To evaluate changes in the speed of pupil constriction and in anterior segment parameters after laser peripheral iridotomy (LPI) in patients with angle closure using anterior segment optical coherence tomography. METHODS In this prospective observational study, videos of pupil and anterior segment changes in response to illumination were captured with real-time video recording using...
متن کاملSenile scleral plaques imaged with enhanced depth optical coherence tomography.
PURPOSE Senile scleral plaques (SSP) are sharply demarcated greyish areas located just anterior to the insertions of the horizontal rectus muscles and thus are frequently encountered during transscleral intravitreal injections. The aim of this study was to characterize SSP using enhanced depth imaging spectral domain anterior segment optical coherence tomography (OCT) in a cohort of patients at...
متن کاملComparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography.
PURPOSE To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadran...
متن کاملEvaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography.
BACKGROUND/AIM To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. MATERIALS AND METHODS Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were take...
متن کاملIn vivo crystalline lens measurements with novel swept-source optical coherent tomography: an investigation on variability of measurement
Objective To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. Methods and analysis One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each...
متن کامل