The efficacy of chemical agents in cleaning and disinfection programs
نویسندگان
چکیده
BACKGROUND Due to the growing number of outbreaks of infection in hospital nurseries, it becomes essential to set up a sanitation program that indicates that the appropriate chemical agent was chosen for application in the most effective way. METHOD For the purpose of evaluating the efficacy of a chemical agent, the minimum inhibitory concentration (MIC) was reached by the classic method of successive broth dilutions. The reference bacteria utilized were Bacillus subtilis var. globigii ATCC 9372, Bacillus stearothermophilus ATCC 7953, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 25923. The strains of Enterobacter cloacae IAL 1976 (Adolfo Lutz Institute), Serratia marcescens IAL 1478 and Acinetobactev calcoaceticus IAL 124 (ATCC 19606), were isolated from material collected from babies involved in outbreaks of infection in hospital nurseries. RESULTS The MIC intervals, which reduced bacteria populations over 08 log10, were: 59 to 156 mg/L of quaternarium ammonium compounds (QACs); 63 to 10000 mg/L of chlorhexidine digluconate; 1375 to 3250 mg/L of glutaraldehyde; 39 to 246 mg/L of formaldehyde; 43750 to 87500 mg/L of isopropanol or ethanol; 1250 to 6250 mg/L of iodine in polyvinyl-pyrolidone complexes, 150 to 4491 mg/L of chlorine-releasing-agents (CRAs); 469 to 2500 mg/L of hydrogen peroxide; and, 2310 to 18500 mg/L of peracetic acid. CONCLUSIONS Chlorhexidine showed non inhibitory activity over germinating spores. A. calcoaceticus, was observed to show resistance to the majority of the agents tested, followed by E. cloacae and S. marcescens.
منابع مشابه
The use of aqueous ozone for cleaning operations in breweries Ozone clean in place in food industries - ozone as an alternative sanitising agent for cleaning operations in food industry
The production of beer is characterized by the consumption of large volumes of fresh water. Whereas, cleaning operations are the highest water consumption demanding activities in breweries. Commonly “Cleaning In Place” (CIP) systems are used in closed processing lines. These consist of automatic cleaning and disinfection programs based on a succession of several solutions of water, cleaning che...
متن کاملLow-Pressure Radiofrequency Cold Plasma for Disinfection of Gutta-Percha Cones
Background and Aim: Different methods have been proposed for rapid disinfection of gutta-percha (GP) cones. This study aimed to assess the efficacy of low-pressure radiofrequency cold plasma (LRFCP) in disinfection of GP cones compared to three chemical disinfectants. Materials and Methods: Seventy GP cones were allocated to seven groups of 10 each. All samples were initially sterilized with e...
متن کاملEvaluating the Cleaning Program Efficacy in ICU Ward of General Hospital Using Visual and Microbial Approaches
Background & Aims of the Study: Hospital infectious is one of the major causes of mortality among the hospitalized cases. The interior environment status of hospitals has the important rule in microbial transmission. Translocation of the infectious agents may be essentially due to contacts between patients and contaminated interior environment. This work was performed to ...
متن کاملAssessing the efficiency of floor disinfection on bacterial decontamination in sanandaj governmental hospitals
Despite regular disinfection and decontamination of the hospital floors and surfaces, resistant pathogens from the hospital surfaces and their transmission to humans have been reported recently. The resistance of pathogens to the disinfectant agents or failed disinfection techniques have put the routine floor and non-critical surface disinfection done in hospitals into question with regard to t...
متن کاملEvaluation of cleaning and disinfection performance of automatic washer disinfectors machines in programs presenting different cycle times and temperatures.
Thermal washer-disinfectors represent a technology that brought about great advantages such as, establishment of protocols, standard operating procedures, reduction in occupational risk of a biological and environmental nature. The efficacy of the cleaning and disinfection obtained by automatic washer disinfectors machines in running programs with different times and temperatures determined by ...
متن کاملDisinfection and general cleaning practices used in health care centers and hospitals
Improving cleaning and disinfection performance must be taken into account for prevention and control of infection. Health care settings are engaged in a battle against healthcare associated infection (HAIs). The importance of infection prevention and control is increasing due to rapidly developing strains of multi-drug resistant organisms (MDROs) that can result in serious illness and even dea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Infectious Diseases
دوره 1 شماره
صفحات -
تاریخ انتشار 2001