Airway scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility.
نویسندگان
چکیده
BACKGROUND /st> Airway Scope is a new videolaryngoscope which requires less cervical movement during intubation than direct laryngoscopy. Thus, in patients wearing a rigid cervical collar, we compared the efficacy of the Airway Scope and the gum elastic bougie with Macintosh laryngoscope during tracheal intubation. METHODS /st> Anaesthesia was induced with propofol, fentanyl, and rocuronium. A rigid cervical collar was applied, and patients were randomly assigned to tracheal intubation with an Airway Scope (n=48) or multiple-use gum elastic bougie with Macintosh laryngoscope (n=48). Measurements included intubation time, gum elastic bougie insertion time, intubation success rate, and insertion and intubation attempts. Airway complications were also recorded. RESULTS /st> The time required for successful intubation was significantly shorter with the Airway Scope compared with the gum elastic bougie with Macintosh laryngoscope [mean (sd) 34 (13) vs 49 (27) s, P=0.001], although the overall success rate of the Airway Scope (100%) compared with the gum elastic bougie with Macintosh laryngoscope (90%) did not reach the statistical significance (P=0.056). Oesophageal intubation (n=8) occurred only with the gum elastic bougie with Macintosh laryngoscope. Incidence of mucosal trauma and lip injury was similar with each device. No dental injury or hypoxia occurred with either device. CONCLUSIONS /st> The Airway Scope shortens intubation time, is less likely to result in oesophageal intubation, and may offer a marginally higher intubation success rate in patients with simulated restricted neck mobility.
منابع مشابه
Evaluation of the success rate and quality of teaching of tracheal intubation to medical students by using video laryngoscope
Background: Training of airway management and tracheal intubation skill in emergencies for resuscitation of patients are basic skills for medical students. However, the success rate of beginners in this skill is low. Video laryngoscopes are new devices that can increase the success of endotracheal intubation training. Methods: This clinical trial was conducted with 30 medical students who came...
متن کاملUtility of a Gum-Elastic Bougie for Difficult Airway Management in Infants: A Simulation-Based Crossover Analysis
BACKGROUND Direct laryngoscopy with the Miller laryngoscope (Mil) for infant tracheal intubation is often difficult to use even for skilled professionals. We performed a simulation trial evaluating the utility of a tracheal tube introducer (gum-elastic bougie (GEB)) in a simulated, difficult infant airway model. METHODS Fifteen anesthesiologists performed tracheal intubation on an infant mani...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملA comparison of the Airway Scope and McCoy laryngoscope in patients with simulated restricted neck mobility.
We compared the efficacy of the Airway Scope and McCoy laryngoscope as intubation tools with the neck stabilised by a rigid cervical collar. After induction of anaesthesia and neck stabilisation, 100 patients were randomly assigned to tracheal intubation with an Airway Scope or McCoy laryngoscope. Overall intubation success rate, time required for intubation, number of intubation attempts requi...
متن کاملComparison of success of tracheal intubation using Macintosh laryngoscope-assisted Bonfils fiberscope and Truview video laryngoscope in simulated difficult airway
BACKGROUND AND AIMS Restriction of head and neck movements prevents the alignment of the oral, pharyngeal, and laryngeal axes and increases the incidence of difficult tracheal intubation in patients with cervical spine fractures. Video laryngoscopes have gained an important role in the management of difficult intubation, especially in situations with limited head and neck movements. This study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 101 6 شماره
صفحات -
تاریخ انتشار 2008