An investigation into contamination of operative suction.

نویسنده

  • C G Greenough
چکیده

A study of the contamination of suckers used during total hip replacement has been undertaken. Thirty suckers used throughout the operation had their tips cultured: from 11 of these bacteria were grown. The organisms found were those which have previously been implicated in deep infection of total hip replacements. In subsequent operations a further 31 suckers were used for cleaning only the femoral shaft; of these only one was contaminated. This suggests that sucker contamination is related to how long the sucker is in use; consequently it is recommended that a new sucker be used for the preparation of the femoral shaft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation into the Pull-out Failure Mechanisms of Suction Caissons

This paper reports results from an investigation into the suction caissons failure mechanisms under vertical pull-out loads. An insight to the failure mechanisms of suction caissons paves the path for developing analytical solutions to their pull-out capacity. The numerical models of suction caissons have first been calibrated by and verified against several experimental data from other researc...

متن کامل

بررسی میزان شیوع عفونت های باکتریایی در دستگاه تنفس شیرخواران تحت تهویه مکانیکی در یکی از بیمارستانهای علومزشکی تهران سال 76-74

The present is a descriptive study aimed at an investigtion into the incidence of bacterial infections in the respiratory system of infans under mechanical ventilation. Use of this instrument is inevitable in cases of respiratory failure or delay, and the air passage should be kept clean by means of a trachea suction thus the problem of pulmonary infection due to handling and entering of partic...

متن کامل

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

متن کامل

An investigation into a Geocell-reinforced Slope in The Unsaturated Numerical Model

Considering unsaturation conditions of soil significantly helps to produce relatively real results. Numerical methods have been assumed as conventional methods in soil mechanics to examine soil behavior. However, the accuracy of numerical methods dramatically depends on applying the appropriate behavioral model to solve problems. One of the known elastoplastic models for unsaturated soils i...

متن کامل

How safe is the suction tip ? Panagiotis

orthopaedic procedures. In the unlikely event of contamination of the system, deep wound infection could occur, jeopardising the operation. We have prospectively studied 50 patients who underwent elective and orthopaedic trauma procedures during which a suction system was used. At the end of each procedure the suction catheter tip was sent for culture and microbiology. The suction tips showed b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 1986