Clinical performance of three bolus calculators in subjects with type 1 diabetes mellitus: a head-to-head-to-head comparison.

نویسندگان

  • Howard Zisser
  • Robin Wagner
  • Stefan Pleus
  • Cornelia Haug
  • Nina Jendrike
  • Chris Parkin
  • Matthias Schweitzer
  • Guido Freckmann
چکیده

BACKGROUND Insulin pump systems now provide automated bolus calculators (ABCs) that electronically calculate insulin boluses to address carbohydrate intake and out-of-range blood glucose (bG) levels. We compared the efficacy of three ABCs (Accu-Chek(®) Combo [Roche Insulin Delivery Systems (IDS), Inc., Fishers, IN, a member of the Roche Group], Animas(®) 2020 [Animas Corp., West Chester, PA, a Johnson and Johnson company], and MiniMed Paradigm Bolus Wizard(®) [Medtronic MiniMed, Northridge, CA]) to safely reduce postprandial hyperglycemia in type 1 diabetes mellitus (T1DM). METHODS T1DM subjects (n = 24) were recruited at a single center for a prospective, triple crossover study. ABCs with the programmed target range (80-140 mg/dL) were used in random order. Postprandial hyperglycemia was induced by reducing the calculated bolus by 25%. Two hours after test meals, the ABCs were allowed to determine whether a correction bolus was needed. Differences between 6-h bG values after test meals that achieved 2-h postprandial hyperglycemia and the mean of the target range (110 mg/dL) were determined. RESULTS The mean difference between 6-h bG levels following test meals and the 110 mg/dL bG target with the MiniMed device (47.4 ± 31.8 mg/dL) was significantly higher than the Animas (17.3 ± 30.9 mg/dL) and Roche IDS (18.8 ± 33.8 mg/dL) devices (P = 0.0022 and P = 0.0049, respectively). The number of meals with 2-h postprandial hyperglycemia and bG levels at 2 h was similar. Roche IDS and Animas devices recommended correction boluses significantly (P = 0.0001 and P = 0.0002, respectively) more frequently than the MiniMed device. ABC use was not associated with severe hypoglycemia. There was no significant difference in the rate of mild hypoglycemia (bG <60 mg/dL not requiring assistance) among the three groups (Roche IDS and Animas, n = 2; MiniMed, n = 0). CONCLUSIONS In this study, the Roche IDS and Animas devices were more efficacious in controlling postprandial hyperglycemia than the MiniMed device. This may be due, in part, to differences in ABC setup protocols and algorithms. Use of ABCs can assist in controlling postprandial glycemia without significant hypoglycemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hearing Status in Patients with Type 2 Diabetes Mellitus According to Blood-Sugar Control: A Comparative Study

Introduction: It seems that diabetes mellitus (DM) can affect the auditory system due to neuropathy, micro-vascular complications, and hearing cell damage during hyperglycemic states. In the current study, we aimed to compare hearing status in patients with type 2 DM (T2DM) according to their blood-sugar control status.   Materials and Methods: This cross-sectional study was carried out in 104 ...

متن کامل

Comparison the Effect of Kinesiotaping with Stretching of Upper Trapezius Muscle in Neck Pain due to Forward Head Posture

Introduction: This research aimed to compare two methods of kinesiotaping and stretching of upper trapezius muscle in treatment of neck pain due to forward head posture. Research Methods: Design of this research was semi-experimental. 36 subjects (29 female and 7 men) with forward head posture between 20-40 years of age with no history of neck pain due to vertebral fracture, disc herniatio...

متن کامل

Demographic and Clinical Characteristics of youth onset Diabetes Mellitus in Kashmir India

Diabetes mellitus (DM) is a major public health problem. Objective of current study was to know the demography, clinical characteristics and etiology of youth Diabetes mellitus (DM) in Kashmir, North India. METHODS: A prospective hospital based study, carried out in the Department of Endocrinology, SKIMS Srinagar, Kashmir India over the period from 2008 July - September 2010. Setting: A teachin...

متن کامل

FPIN's clinical inquiries. Glycemic control in patients with type 2 diabetes.

A systematic review of 63 randomized controlled trials (RCTs) compared A1C reductions among the five classes of oral agents.1 The studies met the following criteria: study period of at least three months, enrollment of at least 10 subjects, and reported A1C reduction. Two groups of trials-monotherapy head-to-head studies (23 trials) and monotherapy versus placebo studies (31 trials)-were compar...

متن کامل

The Antioxidant Effect of Curcumin on Cochlear Fibroblasts in Rat Models of Diabetes Mellitus

Introduction: The aim of this study was to investigate the potential of curcumin as an antioxidant to increase the expression of superoxide dismutase (SOD) in fibroblasts of the cochlear lateral wall in rat models of diabetes mellitus. Materials and Methods: Twenty-four male Wistar rats Rattus norvegicus were randomly divided into six groups: group 1 as the control group; group 2 as the diabeti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 12 12  شماره 

صفحات  -

تاریخ انتشار 2010