Effect of implant abutment modification on the extrusion of excess cement at the crown-abutment margin for cement-retained implant restorations.

نویسندگان

  • Chandur Wadhwani
  • Alfonso Piñeyro
  • Timothy Hess
  • Hai Zhang
  • Kwok-Hung Chung
چکیده

PURPOSE To compare the effect of implant abutment modification on the amount of cement extruded at the crown-abutment margin and to evaluate the vertical discrepancy after cementation. MATERIALS AND METHODS Access openings of titanium abutments were modified with an opening (open) and placement of two vent holes 3 mm from the occlusal edge and 180 degrees apart (internal vent). Access openings were filled with resin material (closed) and used as controls. Each abutment was secured to an implant analog. Eugenol-free zinc oxide cement (TempBond NE) was selected to cement the cast crowns (n = 9) onto test abutments. The amount of cement extruded out of the margin was calculated, and vertical seating discrepancies were determined with a linear transducer device before and after cementation. Differences among groups were analyzed statistically. RESULTS The mean amount of extruded cement ranged from 36% to 90% of the total cement placed within the crowns. The order, from least to greatest amount of excess cement extrusion at the margins, was internal vent, open, and closed; significant differences were observed between test groups. The net vertical discrepancies of tested specimens ranged from -7 μm to +6 μm (mean, 0 μm). No statistically significant differences in vertical discrepancy were found between the groups. CONCLUSIONS Venting the hollow abutment resulted in the least amount of cement extrusion when compared to closing off the screw access channel or leaving it open. Within the limitations of this study, it may be concluded that the use of two, 0.75-mm radius vent holes placed 3 mm apical to the occlusal area of the abutment and 180 degrees apart will limit the amount of cement extruded into the gingival sulcus of implant-retained crowns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A modified technique for extraoral cementation of implant retained restorations for preventing excess cement around the margins

The major drawback of cement-retained restorations is the extrusion of the excess cement into the peri-implant sulcus, with subsequent complications. Insufficient removal of the excess cement may initiate a local inflammatory process, which may lead to implant failure. This article presents a method of controlling cement flow on implant abutments, minimizing the excess cement around implant-ret...

متن کامل

An esthetic solution to the screw-retained implant restoration: introduction to the implant crown adhesive plug: clinical report.

UNLABELLED Screw-retained implant crowns may be clinically demanding, especially managing the esthetic and occlusal challenges of screw access channel closure. Many clinicians have moved away from using screw retention as a means of fixing a crown to an implant in favor of cementation to an underlying abutment. A link has been established between peri-implant disease and excess cement extrusion...

متن کامل

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Cementing an Implant Crown: A Novel Measurement System Using Computational Fluid Dynamics Approach.

BACKGROUND Cementing restorations to implants is a widely used clinical procedure. Little is known about the dynamics of this process. Using a systems approach and advanced computing software modeling this can be investigated virtually. These models require validation against real-life models. PURPOSE The study aims to consider the system effect of a crown, abutment, and cement flow under dif...

متن کامل

Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

OBJECTIVE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. MATERIALS AND M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2011