Prosthetic valve strands.

نویسندگان

  • Edmund Kenneth Kerut
  • Frederick Kushner
چکیده

A 62-year-old woman presented with a sudden transient ischemic attack (TIA). Symptoms resolved within 2 hours of onset. Neurological evaluation and workout for etiology of the TIA was unremarkable. Her medical history included having a St. Jude mitral valve replacement for mitral regurgitation 10 years before presentation. The patient had been maintained on warfarin with INR levels generally in the 3.2–3.6 range. There was no history of atrial dysrhythmia. The admission electrocardiogram was normal. Transthoracic echocardiography (TTE) (Toshiba America, Tustin, CA) was unremarkable except for a mildly enlarged left atrium (LA) measuring 43 mm, with normal left ventricular systolic function noted. The St. Jude mitral prosthesis functioned normally with a normal diastolic gradient. Transesophageal echocardiography (TEE) was performed to evaluate for a cardiac source of embolism. The thoracic aorta was normal and there was no intracardiac shunt detected with saline contrast injections via the antecubital vein. Spontaneous echo contrast was noted near the mouth and within the left atrial appendage, but no thrombus was found. The prosthetic mitral valve was found to function normally, demonstrating a color Doppler short-duration diverging “V” pattern of small nonturbulent “flames” of backflow in the LA during systole (movie clip S1). Multiple mobile filamentous linear echo dense structures were noted within the LA, attached to the prosthetic valve (Fig. 1 and movie clip S2). Based on these TEE findings, a recommendation was made to aggressively maintain an INR > 3 and add lowdose aspirin. Valve strands have been noted since the advent and routine clinical use of TEE. They are linear echo dense structures attached to the mechanical valve and are usually 1–2 mm in width and several mm in length. In distinction, sewing ring sutures are shorter, brighter, and spaced in regular intervals around the ring. Microbubbles are also highly mobile echoes, but move away from the valve during leaflet closure. Valve strands may be associated with native or prosthetic heart valves, and appear to be relatively common, most often attached to mechanical mitral valves. One study (n = 182) found strands in 26% of all patients with an artificial heart valve, with a prevalence of 27% in mechanical and 8% in bioprosthetic valves. By location, they occurred in 32% of mitral and 13% aortic prosthetic valves. Another large study of patients with mechanical heart valves (n = 283) found strands in 38% of prosthetic valves, most often those in the mitral position. Valve strands are likely associated with systemic embolic events. It has been postulated that they may be a marker of inadequate anticoagulation or be indicative of a “pro-thrombotic” state. Strands tend to be associated with older

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of prosthetic valve strands by transesophageal echocardiography: clinical significance in patients with suspected cardiac source of embolism.

OBJECTIVES The purpose of this study was to determine how frequently prosthetic valve strands are associated with prosthetic mitral and aortic valves, as detected by transesophageal echocardiography, and to assess their significance in relation to clinical cardioembolic events. BACKGROUND Strands attached to prosthetic mitral valves are a recently described finding of uncertain clinical signi...

متن کامل

Integrated CT ad MR imaging in alcohol-related isolated left ventricular fatty infiltration.

ment? J Am Soc Echocardiograph 2009;8:895–8. 12. Ionescu AA, Moreno de la Santa P, Dunstan FD, Butchart EG, Fraser AG. Mobile echoes on prosthetic valves are not reproducible. Eur Heart J 1999;20: 140–7. 13. Kiavar M, Sadeghpour A, Bakhshandeh H, Bassiri HA, Tayyebi P, Esmaeilzadeh M et al. Are prosthetic valve fibrin strands negligible? The associations and significance. J Am Soc Echocardiogr ...

متن کامل

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography.

Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as spontaneous echocontrast, microbubbles, strands, sutures, vegetations or thrombus. Doppler echoc...

متن کامل

Novel Application of Tissue Doppler Imaging

Tissue Doppler imaging was used with transthoracic and transesophageal echocardiography to determine its clinical usefulness beyond visualization of ventricular wall motion. Thirteen novel applications were found: acoustically difficult transthoracic studies, thrombus, mitral chordal motion, shunt detection using saline contrast, spontaneous echo contrast, intra-aortic balloon pump position and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Echocardiography

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2014