Effects of air flow on rat electroolfactogram.

نویسندگان

  • P E Scott-Johnson
  • D Blakley
  • J W Scott
چکیده

The electroolfactogram (EOG) previously has been used to demonstrate the regional distribution of rat olfactory epithelial odorant responses. Here, we evaluated the effects of airflow parameters on EOGs in two preparations: one where odorants were directly applied to the epithelium (opened preparation) and one where odorants were drawn through the nasal passages by an artificial sniff (closed preparation). EOG rise times served as one measure of odorant access. For isoamyl acetate (but not for limonene), rise times were slower in the lateral recesses of the closed (but not the opened) preparation. Polar odorants (amyl acetate, carvone and benzaldehyde) evoked smaller responses in the closed preparation than in the opened preparation, and these responses were particularly depressed in the lateral regions of the closed preparation. Responses to nonpolar hydrocarbon odorants (limonene and benzene) were equal in the lateral regions of both preparations, but were somewhat depressed in the medial region of the closed preparation. The responses to some polar odorants in the closed preparation were sensitive to changes in airflow parameters. These data suggest that the sorptive properties of the nose contribute substantially to determining the response of the epithelium and act to increase differences produced by inherent receptor mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of concentration and sniff flow rate on the rat electroolfactogram.

Previous reports using the electroolfactogram (EOG) to study the spatial and temporal aspects of response in the rodent olfactory epithelium had focused on high odorant concentrations that gave large responses. This investigation has used lower concentrations to test the difference between responses in the rat dorsomedial and lateral recesses with a range of nasal flow rates and a range of chem...

متن کامل

Responses of the rat olfactory epithelium to retronasal air flow.

Responses of the rat olfactory epithelium were assessed with the electroolfactogram while odorants were presented to the external nares with an artificial sniff or to the internal nares by positive pressure. A series of seven odorants that varied from very polar, hydrophilic odorants to very nonpolar, hydrophobic odorants were used. Although the polar odorants activated the dorsal olfactory epi...

متن کامل

The Effects of Pressure Difference in Nozzle’s two Phase Flow on the Quality of Exhaust Mixture

In the most application of nozzle with gas-liquid two-phase flow, the quality of mixture in exhaust of nozzle is the most important parameter as well as the flow velocity. On the other hand, in some industrial application, such as water injection in forced induction (turbocharged or supercharged) internal combustion engine the spray quality is the main goal of designing. In this case and for im...

متن کامل

Waste water ammonia stripping intensification using microfluidic system

This paper reports the results of experimentally removing ammonia from synthetically prepared ammonia solution using a micro scale mixing loop air stripper. Effects of various operational parameters (such as: pH, air flow rate, wastewater flow rate and initial ammonia concentration) were evaluated. By increasing the pH from 10 to 12.25 the amount of KLa increased from 0.26 to 0.73 hr-1. A consi...

متن کامل

Effect of Blade Design Parameters on Air Flow through an Axial Fan

The objective of this paper is the numerical study of the flow through an axial fan and examining the effects of blade design parameters on the performance of the fan. The axial fan is extensively used for cooling of the electronic devices and servers. Simulation of the three-dimensional incompressible turbulent flow was conducted by numerical solution of the (RANS) equations for a model. The S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical senses

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2000