Cornea microstructure and mechanical responses measured with nonlinear optical and optical coherence microscopy using sub-10-fs pulses

نویسندگان

  • Qiaofeng Wu
  • Brian E. Applegate
  • Alvin T. Yeh
چکیده

A combined nonlinear optical microscopy (NLOM) and optical coherence microscopy (OCM) imaging system has been assembled in order to simultaneously capture co-registered volumetric images of corneal morphology and biochemistry. Tracking of cell nuclei visible in the OCM volume enabled the calculation of strain depth profile in response to changes in intraocular pressure for rabbit cornea stroma. Results revealed nonlinear responses with a depth dependent strain distribution, exhibiting smaller strains in the anterior and larger strains in the posterior stroma. Cross-sectional images of collagen lamellae, visible in NLOM, showed inhomogeneous collagen structure along the anterior-posterior direction that correlated well with the noted heterogeneous corneal mechanical responses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Responses and Optical Limiting Behavior of Ag Nanoparticle Suspension

In this study, the nonlinear optical properties and optical limiting performance of the silver nanoparticles (AgNPs) in distilled water are investigated. The nonlinear absorption coefficient of the colloid is measured by the Z-scan technique. The optical limiting behavior of the AgNP suspension is investigated under exposure to nanosecond laser pulses at 532 nm. The results show that nonlinear ...

متن کامل

JBO LETTERS Effect of pulse duration on two-photon excited fluorescence and second harmonic generation in nonlinear optical microscopy

We have developed a multiphoton microscopy MPM system using a 12-fs Ti:sapphire laser with adjustable dispersion precompensation in order to examine the impact of pulse duration on nonlinear optical signals. The efficiencies of two-photon-excited fluorescence TPEF and second harmonic generation SHG were studied for various pulse durations, measured at the sample, ranging from 400 fs to sub-20 f...

متن کامل

Effect of pulse duration on two-photon excited fluorescence and second harmonic generation in nonlinear optical microscopy.

We have developed a multiphoton microscopy (MPM) system using a 12-fs Ti:sapphire laser with adjustable dispersion precompensation in order to examine the impact of pulse duration on nonlinear optical signals. The efficiencies of two-photon-excited fluorescence (TPEF) and second harmonic generation (SHG) were studied for various pulse durations, measured at the sample, ranging from approximatel...

متن کامل

Simultaneous second-harmonic generation, third-harmonic generation, and four-wave mixing microscopy with single sub-8 fs laser pulses

We demonstrate a compact pulse compression scheme that offers flexible chirp control for improved conversion efficiencies in high resolution nonlinear optical microscopy. An Er:fiber laser combined with a highly nonlinear optical fiber yields pulses centered at 1100 nm with a bandwidth of 500 nm. The compressed pulses with a duration of 7.6 fs enable simultaneous second-harmonic generation, thi...

متن کامل

Multimodal microscopy with sub-30 fs Yb fiber laser oscillator

Nonlinear optical microscopy with sub-30 fs pulses from an Yb-fiber laser, approximately three times shorter than typical fiber laser pulses, leads to an order of magnitude brighter third harmonic generation imaging. Multiphoton fluorescence, second and third harmonic generation modalities are compared on stained microspheres and unstained biological tissues.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011